Physical properties of endovascular stents: An experimental comparison

被引:164
作者
Duda, SH
Wiskirchen, J
Tepe, G
Bitzer, M
Kaulich, TW
Stoeckel, D
Claussen, CD
机构
[1] Univ Tubingen, Div Diagnost Radiol, Dept Radiol, D-72076 Tubingen, Germany
[2] Nitinol Devices & Components, Fremont, CA USA
关键词
arteries; grafts and prostheses; transluminal angioplasty; fluoroscopy; stents and prostheses;
D O I
10.1016/S1051-0443(07)61620-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Different endovascular stent types (AVE Bridge, AVE Bridge X, Memotherm, Palmaz Large, Palmaz Medium, Palmaz-Schatz Long-Medium, Perflex, S.M.A.R.T., Symphony, and Wallstent) of 4 cm length and 8 mm diameter were subjected to standardized physical tests, MATERIALS AND METHODS: The metal mass of each stent was assessed by weighing. The balloon-expandable stents were pneumatically tested for hoop strength. In self-expanding stents, radial resistive force and chronic outward force were determined with use of a loop test. Stent delivery system pushability was assessed in a crossover model. Stent radiopacity was analyzed quantitatively, RESULTS: The hoop strength of the balloon-expandable stents ranged from 15.8 N/cm (Perflex) to 28.9 N/cm (AVE Bridge X), The stent weight increased with greater hoop strength (Perflex, 0.046 g/cm vs. AVE Bridge X, 0.061 g/cm), The self-expanding stents had a radial resistive force between 0.39 N/cm (Wallstent) and 1.7 N/cm (Smart), The flexible balloon-expandable stents showed pushability values between 0.13/N (AVE Bridge) and 0.20/N (Perflex), The self-expanding stents had flexibilities between 0.13/N (Memotherm) and 0.24/N (Symphony), Radiopacity assessed with use of a phantom simulating the iliac region ranged from 92 (Palmaz Large) to 115 (AVE Bridge) on a 256-point gray scale (0 = black, 256 = white). CONCLUSIONS: There is no stent with ideal physical properties. However, depending on the characteristics of the arterial lesion to be treated, the most appropriate stent can be chosen.
引用
收藏
页码:645 / 654
页数:10
相关论文
共 40 条
[1]   CHANGES IN ARTERIAL-WALL COMPLIANCE AFTER ENDOVASCULAR STENTING [J].
BACK, M ;
KOPCHOK, G ;
MUELLER, M ;
CAVAYE, D ;
DONAYRE, C ;
WHITE, RA .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) :905-911
[2]   Paired comparison of vascular wall reactions to Palmaz stents, Strecker tantalum stents, and Wallstents in canine iliac and femoral arteries [J].
Barth, KH ;
Virmani, R ;
Froelich, J ;
Takeda, T ;
Lossef, SV ;
Newsome, J ;
Jones, R ;
Lindisch, D .
CIRCULATION, 1996, 93 (12) :2161-2169
[3]   A method to evaluate the elastic behavior of vascular stents [J].
Berry, JL ;
Newman, VS ;
Ferrario, CM ;
Routh, WD ;
Dean, RH .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (03) :381-385
[4]   IN-VITRO MODEL TO TEST THE THROMBOGENICITY OF CORONARY STENTS [J].
BEYTHIEN, C ;
TERRES, W ;
HAMM, CW .
THROMBOSIS RESEARCH, 1994, 75 (06) :581-590
[5]   COLLAPSE OF A PALMAZ STENT IN THE SUBCLAVIAN VEIN [J].
BJARNASON, H ;
HUNTER, DW ;
CRAIN, MR ;
FERRAL, H ;
MILTZMILLER, SE ;
WEGRYN, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) :1123-1124
[6]   EFFECT OF LOW-TEMPERATURE PHASE CHANGES ON MECHANICAL PROPERTIES OF ALLOYS NEAR COMPOSITION TINI [J].
BUEHLER, WJ ;
WILEY, RC ;
GILFRICH, JV .
JOURNAL OF APPLIED PHYSICS, 1963, 34 (05) :1475-&
[7]  
Carter AJ, 1998, CATHETER CARDIO DIAG, V44, P193, DOI 10.1002/(SICI)1097-0304(199806)44:2<193::AID-CCD13>3.3.CO
[8]  
2-2
[9]   An apparatus to measure the shape memory properties of nitinol tubes for medical applications [J].
Chen, JT ;
Duerig, TW ;
Pelton, AR ;
Stockel, D .
JOURNAL DE PHYSIQUE IV, 1995, 5 (C8) :1247-1252
[10]   NITINOL INTRAVASCULAR STENT - RESULTS OF PRECLINICAL EVALUATION [J].
CRAGG, AH ;
DEJONG, SC ;
BARNHART, WH ;
LANDAS, SK ;
SMITH, TP .
RADIOLOGY, 1993, 189 (03) :775-778