Shading performance of a vertical deciduous climbing plant canopy

被引:113
作者
Ip, Kenneth [1 ]
Lam, Marta [1 ]
Miller, Andrew [1 ]
机构
[1] Univ Brighton, Ctr Sustainabil Built Environm, Sch Environm & Technol, Brighton BN2 4GJ, E Sussex, England
关键词
External shading device; Deciduous climbing plant canopy; Shading coefficient; Bioshading Coefficient; Bioshader;
D O I
10.1016/j.buildenv.2009.05.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Deciduous climbing plant canopies strategically integrated to building facades can act as dynamic solar shading devices responsive to the seasonal climatic changes. Maximum shading occurs in the summer when the plant is at its peak growth. The shedding of leaves in autumn and winter reduces the shading and allows beneficial solar radiation to be absorbed by the opaque surface of the building facade or penetrated through the windows to the building interior. Although climbing plants have long been used for moderating the microclimate of buildings, there are very few scientific investigations to quantify such effects. This paper reports the findings of a study with specific focus on the shading performance of a vertical deciduous climbing plant canopy. It justifies the selection of Virginia Creeper as an appropriate plant for growth in the UK climate and describes the planting, monitoring and analysis procedures adopted to determine a proposed dynamic Bioshading Coefficient Function - which is used to represent the shading performance of the climbing plant canopy over its annual growing and wilting cycle. A thermal model was developed which identified the key parameters required for establishing the Bioshading Coefficients. Two climbing plant canopies (referred to as Bioshaders) were set up in an existing building in Southeast UK and monitored for 2 years. Measured data were used to calculate a series of daily Bioshading Coefficients which were subsequently applied to establish the Bioshading Coefficient Function. The research also identified issues affecting the indoor environment as a result of the application of Bioshaders. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 18 条
[1]   Reductions in air conditioning energy caused by a nearby park [J].
Ca, VT ;
Asaeda, T ;
Abu, EM .
ENERGY AND BUILDINGS, 1998, 29 (01) :83-92
[2]  
CANTUARIA G, 2000, PLEA ARCHITECTURE CI
[3]  
*CIBSE, 2006, CIBSE GUID ENV DES
[4]   Cooling effect of ivy ion a wall [J].
Di, HF ;
Wang, DN .
EXPERIMENTAL HEAT TRANSFER, 1999, 12 (03) :235-245
[5]  
Grant G., 2006, Green roofs and facades
[6]  
HAYANO A, 1988, ENERG BUILDINGS, V11, P181
[8]  
IP K, 2004, CIB WORLD BUILD C MA
[9]  
LAM HY, 2007, SCH ENV
[10]  
Lam M., 2002, Sustainable buildings 2002 - third international conference on sustainable buildings