Bead injection for surface enhanced Raman spectroscopy:: automated on-line monitoring of substrate generation and application in quantitative analysis

被引:25
作者
Cañada, MJA
Medina, AR
Frank, J
Lendl, B
机构
[1] Vienna Univ Technol, Inst Chem Technol & Analyt, A-1060 Vienna, Austria
[2] Univ Jaen, Dept Phys & Analyt Chem, E-23071 Jaen, Spain
关键词
D O I
10.1039/b204073e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The technique of bead injection has been adapted for surface enhanced Raman scattering (SERS) to substantially improve precision, long term stability and sensitivity of SERS detection in analytical chemistry. For this purpose a fully automated flow system comprising a dedicated flow-cell has been developed and tested. With the developed flow-cell, which contains two inlet and two outlet channels, it is possible to retain, perfuse and discharge minute amounts of polymer beads while monitoring all steps by Raman spectroscopy. First, beads carrying cation exchanger moieties were retained in the flow-cell and subsequently perfused with a silver nitrate and a hydroxylamine solution using one inlet of the flow cell. By this sequence homogeneous SERS active silver layers were formed on the beads. The uniformity of the achieved silver layer was studied by secondary electron microscopy. For measurement, the analyte was then introduced from the second inlet channel such that the interaction between the activated SERS beads and analyte occurred in close proximity and within the focus of the laser excitation beam. Due to the complete computer control of all experimental steps, including bead entrapment, SERS layer generation, sample introduction and final bead removal, highly reproducible conditions for SERS were achieved. The method was developed using 9-aminoacridine as a test molecule. Quantitative studies were carried out for 9-aminoacridine and acridine showing linear calibrations from 1-100 nmol l(-1) and 50-1000 nmol l(-1), respectively, using a sample volume of 200 mul each. Typical relative standard deviations were 4.7% for 9-aminoacrine and 5.8% for acridine.
引用
收藏
页码:1365 / 1369
页数:5
相关论文
共 19 条
[1]   Novel preparation procedure for NIR-SERS measurements by using ion exchangers to provide highly improved signal enhancement and stability [J].
Ayora-Cañada, MJ ;
Pascual-Reguera, MI ;
Ballesteros, L ;
Molina-Díaz, A .
APPLIED SPECTROSCOPY, 2001, 55 (02) :227-232
[2]   Flow-injection analysis and liquid chromatography: Surface-enhanced Raman spectrometry detection by using a windowless flow cell [J].
Cabalin, LM ;
Ruperez, A ;
Laserna, JJ .
ANALYTICA CHIMICA ACTA, 1996, 318 (02) :203-210
[3]   Study of biomolecules by combining electrochemistry with UV/Vis, IR and surface enhanced Raman scattering spectroscopy by a novel flow microcell [J].
Chen, HY ;
Long, YT .
ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) :171-177
[5]   DETECTION OF AROMATICS IN AQUEOUS-SOLUTION BY SURFACE-ENHANCED RAMAN-SCATTERING BY SUBSTRATES CHEMICALLY-MODIFIED WITH P-TERT-BUTYLCALIX[4]ARENETETRATHIOL [J].
HILL, W ;
WEHLING, B ;
GIBBS, CG ;
GUTSCHE, CD ;
KLOCKOW, D .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3187-3192
[6]   Development of a cascade flow cell for dynamic aqueous phase detection using modified SERS substrates [J].
Kennedy, BJ ;
Milofsky, R ;
Carron, KT .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4708-4715
[7]   MIXTURE ANALYSIS AND QUANTITATIVE-DETERMINATION OF NITROGEN-CONTAINING ORGANIC-MOLECULES BY SURFACE-ENHANCED RAMAN SPECTROMETRY [J].
LASERNA, JJ ;
CAMPIGLIA, AD ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1989, 61 (15) :1697-1701
[8]   Flow analysis-based surface-enhanced Raman spectroscopy employing exchangeable microbeads as SERS-active surfaces [J].
Lendl, B ;
Ehmoser, H ;
Frank, J ;
Schindler, R .
APPLIED SPECTROSCOPY, 2000, 54 (07) :1012-1018
[9]   ADSORPTION OF CHLORINATED ETHYLENES AT 1-OCTADECANETHIOL-MODIFIED SILVER SURFACES [J].
MULLEN, K ;
CARRON, K .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :478-483
[10]   FLOW-INJECTION ANALYSIS AND REAL-TIME DETECTION OF RNA BASES BY SURFACE-ENHANCED RAMAN-SPECTROSCOPY [J].
NI, F ;
SHENG, RS ;
COTTON, TM .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1958-1963