Noninvasive cerebral oximeter as a surrogate for mixed venous saturation in children

被引:53
作者
Bhutta, Adnan T. [1 ]
Ford, Jesse W.
Parker, James G.
Prodhan, Parthak
Fontenot, Eudice E.
Seib, Paul M.
Stroope, Brittany I.
Frazier, Elizabeth A.
Schmitz, Michael L.
Drummond-Webb, Jonathan J.
Morrow, William R.
机构
[1] Univ Arkansas Med Sci, Dept Pediat, Little Rock, AR 72202 USA
[2] Arkansas Childrens Hosp, Little Rock, AR 72202 USA
[3] Univ Arkansas Med Sci, Dept Anesthesiol, Little Rock, AR 72202 USA
[4] Univ Arkansas Med Sci, Dept Surg, Little Rock, AR 72202 USA
关键词
pediatrics; near-infrared spectroscopy; cardiac catheterization; mixed venous saturation; central venous saturation; oxygen consumption;
D O I
10.1007/s00246-006-1379-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the relationship between regional cerebral oxygen saturation (rSO(2)) measured by near-infrared spectroscopy (NIRS) cerebral oximeter with superior vena cava (SVC), inferior vena cava (IVC), right atrium (RA), and pulmonary artery (PA) saturation measured on room air and 100% inspired oxygen administered via a non-rebreather mask (NRB) in children. Twenty nine pediatric post-orthotopic heart transplant patients undergoing an annual myocardial biopsy were studied. We found a statistically significant correlation between rSO(2) and SVC saturations at room air and 100% inspired oxygen concentration via NRB (r = 0.67, p = 0.0002 on room air; r = 0.44, p = 0.02 on NRB), RA saturation (r = 0.56, p = 0.002; r = 0.56, p = 0.002), and PA saturation ( r = 0.67, p < 0.001; r = 0.4, p = 0.03). A significant correlation also existed between rSO(2) and measured cardiac index (r = 0.45, p = 0.01) and hemoglobin levels (r = 0.41, p = 0.02). The concordance correlations were fair to moderate. Bias and precision of rSO(2) compared to PA saturations on room air were - 0.8 and 13.9%, and they were 2.1 and 15.6% on NRB. A stepwise linear regression analysis showed that rSO(2) saturations were the best predictor of PA saturations on both room air (p = 0.0001) and NRB (p = 0.012). In children with biventricular anatomy, rSO(2) readings do correlate with mixed venous saturation.
引用
收藏
页码:34 / 41
页数:8
相关论文
共 48 条
[1]   Cerebral oxygen monitoring during neonatal cardiopulmonary bypass and deep hypothermic circulatory arrest [J].
Abdul-Khaliq, H ;
Troitzsch, D ;
Schubert, S ;
Wehsack, A ;
Böttcher, W ;
Gutsch, E ;
Hübler, M ;
Hetzer, R ;
Lange, PE .
THORACIC AND CARDIOVASCULAR SURGEON, 2002, 50 (02) :77-81
[2]   Dynamic changes in cerebral oxygenation related to deep hypothermia and circulatory arrest evaluated by near-infrared spectroscopy [J].
Abdul-Khaliq, H ;
Schubert, S ;
Troitzsch, D ;
Huebler, M ;
Boettcher, W ;
Baur, MO ;
Lange, PE .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (06) :696-701
[3]   Neurological monitoring for congenital heart surgery [J].
Andropoulos, DB ;
Stayer, SA ;
Diaz, LK ;
Ramamoorthy, C .
ANESTHESIA AND ANALGESIA, 2004, 99 (05) :1365-1375
[4]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[5]   Regional blood flow during exercise in humans measured by near-infrared spectroscopy and indocyanine green [J].
Boushel, R ;
Langberg, H ;
Olesen, J ;
Nowak, M ;
Simonsen, L ;
Bülow, J ;
Kjær, M .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 89 (05) :1868-1878
[6]  
CASATI A, 2004, AM SOC AN ANN M LAS
[7]  
DELAROCHA AG, 1978, CAN J SURG, V21, P227
[8]   MEASUREMENT OF HEMOGLOBIN FLOW AND BLOOD-FLOW BY NEAR-INFRARED SPECTROSCOPY [J].
EDWARDS, AD ;
RICHARDSON, C ;
VANDERZEE, P ;
ELWELL, C ;
WYATT, JS ;
COPE, M ;
DELPY, DT ;
REYNOLDS, EOR .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (04) :1884-1889
[9]  
Fernandez Edward G, 2004, Pediatr Crit Care Med, V5, P14, DOI 10.1097/01.PCC.0000102383.07075.97
[10]  
FORTUNE PM, 2004, INTENS CARE MED, V27, P1401