Novel bioengineered small caliber vascular graft with excellent one-month patency

被引:16
作者
Ishii, Yosuke
Kronengold, Russell T.
Virmani, Renu
Rivera, Elias A.
Goldman, Scott M.
Prechtel, Ericka J.
Schuessler, Richard B.
Damiano, Ralph J., Jr.
机构
[1] Washington Univ, Sch Med, Div Cardiothorac Surg, St Louis, MO 63110 USA
[2] Kensey Nash Corp, Exton, PA USA
[3] Armed Forces Inst Pathol, Dept Infect & Parasit Dis Pathol, Amer Registry Pathol, Washington, DC 20306 USA
关键词
D O I
10.1016/j.athoracsur.2006.09.053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. A bioengineered microporous polycarbonatesiloxane polyurethane graft has been developed for coronary artery bypass grafting. Biological agents can be impregnated into its absorbable collagen and hyaluronan microstructure and stable macrostructure to promote patency. The objective of this study was to examine the biological performance and biomechanical characteristics of this graft. Methods. Heparin-sirolimus (HS) or heparin-sirolimus -vascular endothealial growth factor (HSV) grafts were manufactured for this study. Heparin ( 40 U) was embedded in the microstructure of the graft for early elution from the graft wall. Heparin ( 100 U) and sirolimus ( 450 mu g) were incorporated into the macrostructure of the graft for late elution. Vascular endothelial growth factor was also embedded in the microstructure of the graft. Both grafts ( 3.6 mm internal diameter, 24 mm length) were implanted into the abdominal aortas of rabbits ( n = 36) to compare with heparin-alone ( H) grafts ( n = 9). At 4 hours, 1 day, and 1, 2, and 4 weeks after surgery, the grafts were removed for histologic, immunohistochemical, and biomechanical evaluations. Results. The patency rate of all grafts was 100% at each time point. None of grafts had stenosis after surgery. Endothelial cells were observed at 4 weeks after surgery in the HS, HSV, and H grafts. Although there was no significant difference of neointima thickness among the HS, HSV, and H grafts ( 136 +/- 75, 93 +/- 64, and 125 +/- 90 mu m; p = 0.08), the H grafts did have more cellular infiltration in the graft than the HS or HSV grafts. There was neocapillary formation inside the graft wall at 4 weeks in all grafts. The graft macrostructure was unchanged based on biomechanical evaluation 4 weeks after surgery. Conclusions. A unique drug-eluting graft had excellent patency at 1 month and may encourage luminal endothelialization without excessive intimal hyperplasia. Although vascular endothelial growth factor did not improve intimal formation, cell infiltration, or vascularization, sirolimus might inhibit cell proliferation. Further long-term study would need to evaluate the efficacy of impregnated sirolimus. (c) 2007 by The Society of Thoracic Surgeons.
引用
收藏
页码:517 / 525
页数:9
相关论文
共 26 条
[1]   THE FUTURE OF SAPHENOUS-VEIN AS A CORONARY-ARTERY BYPASS CONDUIT [J].
ANGELINI, GD ;
NEWBY, AC .
EUROPEAN HEART JOURNAL, 1989, 10 (03) :273-280
[2]   SMALL-CALIBER POLYURETHANE AND POLYTETRAFLUOROETHYLENE GRAFTS - A COMPARATIVE-STUDY IN A CANINE AORTOILIAC MODEL [J].
BROTHERS, TE ;
STANLEY, JC ;
BURKEL, WE ;
GRAHAM, LM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (06) :761-771
[3]   Neointimal formation after balloon-induced vascular injury in Yucatan minipigs is reduced by oral rapamycin [J].
Burke, SE ;
Lubbers, NL ;
Chen, YW ;
Hsieh, GC ;
Mollison, KW ;
Luly, JR ;
Wegner, CD .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1999, 33 (06) :829-835
[4]   Coronary bypass surgery with internal-thoracic-artery grafts - Effects on survival over a 15-year period [J].
Cameron, A ;
Davis, KB ;
Green, G ;
Schaff, HV .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (04) :216-219
[5]   Development and evaluation of a novel decellularized vascular xenograft [J].
Conklin, BS ;
Richter, ER ;
Kreutziger, KL ;
Zhong, DS ;
Chen, C .
MEDICAL ENGINEERING & PHYSICS, 2002, 24 (03) :173-183
[6]   Seeding of vascular grafts with genetically modified endothelial cells - Secretion of recombinant TPA results in decreased seeded cell retention in vitro and in vivo [J].
Dunn, PF ;
Newman, KD ;
Jones, M ;
Yamada, I ;
Shayani, V ;
Virmani, R ;
Dichek, DA .
CIRCULATION, 1996, 93 (07) :1439-1446
[7]  
Eberhart A, 1999, J BIOMED MATER RES, V48, P546, DOI 10.1002/(SICI)1097-4636(1999)48:4<546::AID-JBM22>3.3.CO
[8]  
2-M
[9]  
ESQUIVEL CO, 1984, SURGERY, V95, P102
[10]   WHY SMALL CALIBER VASCULAR GRAFTS FAIL - A REVIEW OF CLINICAL AND EXPERIMENTAL EXPERIENCE AND THE SIGNIFICANCE OF THE INTERACTION OF BLOOD AT THE INTERFACE [J].
ESQUIVEL, CO ;
BLAISDELL, FW .
JOURNAL OF SURGICAL RESEARCH, 1986, 41 (01) :1-15