Glycaemic control in type 2 diabetic patients on chronic haemodialysis: use of a continuous glucose monitoring system

被引:95
作者
Riveline, Jean-Pierre [2 ]
Teynie, Julie [1 ,3 ,4 ]
Belmouaz, Simohamed [1 ,3 ,4 ]
Franc, Sylvia [2 ]
Dardari, Dured [2 ]
Bauwens, Marc [1 ,3 ,4 ]
Caudwell, Valerie [5 ]
Ragot, Stephanie [6 ]
Bridoux, Frank [1 ,3 ,4 ]
Charpentier, Guillaume [2 ]
Marechaud, Richard [1 ]
Hadjadj, Samy [1 ,3 ,4 ,6 ,7 ]
机构
[1] CHU Poitiers, F-86021 Poitiers, France
[2] Ctr Hosp Sud Francilien, Serv Diabetol, F-91100 Corbeil Essonnes, France
[3] Fac Med Pharm, F-86000 Poitiers, France
[4] Univ Poitiers, F-86014 Poitiers, France
[5] Ctr Hosp Sud Francilien, Serv Nephrol, F-91080 Courcouronnes, France
[6] CHU Poitiers, INSERM, CIC 802, F-86021 Poitiers, France
[7] INSERM, U927, F-86021 Poitiers, France
关键词
CGMS; diabetes; dialysis; end-stage renal failure; haemodialysis; PEDIATRIC-PATIENTS; BLOOD-GLUCOSE; GLYCATED ALBUMIN; RENAL-DISEASE; SURVIVAL; END; HEMOGLOBIN; IMPACT;
D O I
10.1093/ndt/gfp181
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Methods. We used a 4-day CGMS to monitor glucose levels in 19 haemodialysed type 2 diabetic patients (HD T2) including 2 days with and 2 days without dialysis session, and 39 non-HD T2 in a double-centre study. Results. The glucose concentration according to the glucose meter and CGMS were correlated in HD T2 patients (r = 0.90, P < 0.0001) and in non-HD T2 patients (r = 0.81, P < 0.0001). The relative absolute difference (RAD) between glucose determined by a glucose meter and glucose determined by the CGMS did not differ between HD T2 and non-HD T2 patients (9.2 +/- 10.5 vs. 8.2 +/- 7.6%; P = 0.165). Glycated haemoglobin (A1c) and mean glucose concentration were strongly correlated in non-HD T2 patients (r = 0.71; P < 0.0001) but weakly correlated in HD T2 patients (r = 0.47; P = 0.042). Fructosamine was correlated with the mean glucose concentration in non-HD T2 (r = 0.67; P < 0.0001) but not in HD T2 patients (r = 0.04; P = 0.88). Conclusion. CGM is a validated marker of glycaemic control in HD diabetic patients. This tool showed that A1c and fructosamine, despite being good markers of glycaemic control in non-HD diabetic patients, are of poor value in HD diabetic patients.
引用
收藏
页码:2866 / 2871
页数:6
相关论文
共 39 条
[1]   Plasma insulin is removed by hemodialysis: Evaluation of the relation between plasma insulin and glucose by using a dialysate with or without glucose [J].
Abe, Masanori ;
Kaizu, Kazo ;
Matsumoto, Koichi .
THERAPEUTIC APHERESIS AND DIALYSIS, 2007, 11 (04) :280-287
[2]  
[Anonymous], 2008, Am J Kidney Dis, V51, pS1
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Limitations of conventional methods of self-monitoring of blood glucose - Lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes [J].
Boland, E ;
Monsod, T ;
Delucia, M ;
Brandt, CA ;
Fernando, S ;
Tamborlane, WV .
DIABETES CARE, 2001, 24 (11) :1858-1862
[5]   The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control [J].
Chico, A ;
Vidal-Ríos, P ;
Subirà, M ;
Novials, A .
DIABETES CARE, 2003, 26 (04) :1153-1157
[6]   Indicators for blood glucose control in diabetics with end - stage chronic renal disease : GHb vs. glycated albumin (GA) [J].
Chujo, Keiko ;
Shima, Kenji ;
Tada, Hiroaki ;
Oohashi, Teruyo ;
Minakuchi, Jun ;
Kawashima, Syu .
JOURNAL OF MEDICAL INVESTIGATION, 2006, 53 (3-4) :223-228
[7]   Prevalence of chronic kidney disease in the United States [J].
Coresh, Josef ;
Selvin, Elizabeth ;
Stevens, Lesley A. ;
Manzi, Jane ;
Kusek, John W. ;
Eggers, Paul ;
Van Lente, Frederick ;
Levey, Andrew S. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (17) :2038-2047
[8]   GLYCOSYLATED HEMOGLOBIN IN CHRONIC RENAL-FAILURE [J].
DANDONA, P ;
FREEDMAN, D ;
MOORHEAD, JF .
BMJ-BRITISH MEDICAL JOURNAL, 1979, 1 (6172) :1183-1184
[9]   GLYCOSYLATED HEMOGLOBIN IN RENAL-FAILURE [J].
DEBOER, MJ ;
MIEDEMA, K ;
CASPARIE, AF .
DIABETOLOGIA, 1980, 18 (06) :437-440
[10]   Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring [J].
Deis, Dorothee ;
Bolinder, Jan ;
Riveline, Jean-Pierre ;
Battelino, Tadej ;
Bosi, Emanuele ;
Tubiana-Rufi, Nadia ;
Kerr, David ;
Phillip, Moshe .
DIABETES CARE, 2006, 29 (12) :2730-2732