Novel use of a dual-zone restricted access sorbent: normal-phase solid-phase extraction separation of methyl oleate from polynuclear aromatic hydrocarbons stemming from semi-permeable membrane devices

被引:6
作者
Gustavson, KE
DeVita, WM
Revis, A
Harkin, JM
机构
[1] Univ Wisconsin, Ctr Environm Toxicol, Madison, WI 53706 USA
[2] Univ Wisconsin, Water Resources Inst, Madison, WI 53706 USA
[3] Univ Wisconsin, Coll Nat Resources, Stevens Point, WI 54481 USA
[4] Diazem Corp, Midland, MI 48640 USA
关键词
solid-phase extraction; membranes; restricted-access media; sorbents; methyl oleate; polynuclear aromatic hydrocarbons;
D O I
10.1016/S0021-9673(00)00362-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A normal-phase solid-phase extraction (SPE) method was developed utilizing a dual-zone restricted-access sorbent to separate methyl oleate from the 16 US Environmental Protection Agency priority-pollutant polynuclear aromatic hydrocarbons in a hexane matrix. This technique represents a new development in SPE methodology expanding the limited number of available normal-phase SPE sorbents. While based on a specific application (removal of methyl oleate from semipermeable membrane device extracts), this cleanup method could easily be adapted for other uses requiring the removal/isolation of methyl oleate and potentially related compounds. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 16 条
[1]  
[Anonymous], TECHNIQUES AQUATIC T
[2]   Determination of aqueous concentrations of polycyclic aromatic hydrocarbons (PAHs) in an urban stream [J].
Crunkilton, RL ;
DeVita, WM .
CHEMOSPHERE, 1997, 35 (07) :1447-1463
[3]  
ELLIS GS, 1995, ENVIRON TOXICOL CHEM, V14, P1875, DOI [10.1897/1552-8618(1995)14[1875:EOLSMD]2.0.CO
[4]  
2, 10.1002/etc.5620141109]
[6]   Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography [J].
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :3-54
[7]   LIPID-CONTAINING SEMIPERMEABLE-MEMBRANE DEVICES FOR MONITORING ORGANIC CONTAMINANTS IN WATER [J].
HUCKINS, JN ;
MANUWEERA, GK ;
PETTY, JD ;
MACKAY, D ;
LEBO, JA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (12) :2489-2496
[8]   USE OF THE SEMIPERMEABLE-MEMBRANE DEVICE AS AN IN-SITU SAMPLER OF WATERBORNE BIOAVAILABLE PCDD AND PCDF RESIDUES AT SUB-PARTS-PER-QUADRILLION CONCENTRATIONS [J].
LEBO, JA ;
GALE, RW ;
PETTY, JD ;
TILLITT, DE ;
HUCKINS, JN ;
MEADOWS, JC ;
ORAZIO, CE ;
ECHOLS, KR ;
SCHROEDER, DJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (11) :2886-2892
[9]  
LEBO JA, COMMUNICATION
[10]  
Mackay D, 1992, ILLUSTRATED HDB PHYS