Results of metal-metal-bearing for Hofer-Imhof-socket

被引:6
作者
Bachfischer, K [1 ]
Karp, PM [1 ]
Schwarz, R [1 ]
机构
[1] Tech Univ Munich, Klin & Poliklin Orthopad & Sportorthopadie, Klinikum Rechts Isar, D-81675 Munich, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE | 2000年 / 138卷 / 03期
关键词
total hip replacement; metal-metal-bearing; solid metal inlay; heterotopic ossifications;
D O I
10.1055/s-2000-10141
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Question: The conically clamping inlay of solid metal for the Hofer-Imhof threaded socket makes possible the use of a metal-metal-bearing by completely dispensing with polyethylen but keeping the four-elements-construction of THR. In order to preceive long-term problems and complications patients of our hospital who took part in a closed multi-center-study which was established prospectively were checked again. Method: Clinical and X-ray examination of 27 patients after 19 months on an average (12-23 months). Results: Harris-score increased from 38 points before the operation to 89 points three months after the operation and 91 points in the present check-up. Three months after the operation 22 patients were free of pain, at present only 12. X-Rays did not show any signs of loosening within the prostheses. But increasing ectopic ossifications of Brooker were found: ten times Class I, once Class II and six times Class III. Conclusion: Using equal form of after treatment the increasing break out of pain as well as the growing symptom of ectopic ossifications in the hip area after the implantation of the Hofer-Imhof threaded socket with solid metal inlay is presumably caused by the use of the metal-metal-bearing as well as by the direct lining of the Co-Cr-inlay in the titan-socket and by possible changes in corrosion.
引用
收藏
页码:230 / 234
页数:5
相关论文
共 46 条
[1]
AMSTUTZ HC, 1996, CLIN ORTHOP S, V329, pS11
[2]
BETTS F, 1992, CLIN ORTHOP RELAT R, P75
[3]
BLACK J, 1996, CLIN ORTHOP S, V329, pS244
[4]
Doorn PF, 1996, CLIN ORTHOP RELAT R, pS187
[5]
Indomethacin for prevention of heterotopic ossification after hip arthroplasty - A randomized comparison between 4 and 8 days of treatment [J].
Dorn, U ;
Grethen, C ;
Effenberger, H ;
Berka, H ;
Ramsauer, T ;
Drekonja, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (02) :107-110
[6]
Dorr LD, 1996, CLIN ORTHOP RELAT R, P108
[7]
EFFENBERGER H, 1995, POST 22 JAHR EIS
[8]
PERIARTICULAR OSSIFICATIONS AFTER IMPLANTING ZWEYMULLER-ENDLER TOTAL HIP PROSTHESES [J].
EYB, R ;
ZWEYMULLER, K .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1985, 123 (06) :975-980
[9]
FRANEK F, ZWEYM SYST 15 JAHR E, P9
[10]
GOODMAN SB, 1997, CLIN ORTHOP RELAT R, V337, pS149