System for automatic selection of operating conditions for inductively coupled plasma atomic emission spectroscopy

被引:19
作者
Branagh, W [1 ]
Whelan, C [1 ]
Salin, ED [1 ]
机构
[1] MCGILL UNIV,DEPT CHEM,MONTREAL,PQ H3A 2K6,CANADA
关键词
matrix effects; analysis parameters; inductively coupled plasma atomic emission spectroscopy; expert systems;
D O I
10.1039/a704601d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The design of a system for automatic parameter and methodology selection for inductively coupled plasma atomic emission spectroscopy (ICP-AES) is presented, The ICP is an excellent excitation source that suffers less from matrix effects than other sources but is not altogether problem-free, To compensate, a variety of methodologies and approaches can be used to minimize matrix-induced error present in an analysis, For example, one can prepare matrix-matched standards, use standard additions or select instrumental parameters (rf power, pump rate and viewing height) specifically for the analytes of interest, Ideally, an Autonomous Instrument, operating without human intervention, needs to have the ability to determine the analytical parameters and methodology to apply to a sample, A measure of expected analytical error for a sample to be used by an Autonomous Instrument, the total interference level (TIL), is introduced, The TIL applies the results from a semiquantitative scan to a 'lookup' table to determine what the approximate expected error will be, It relies on a 'conservative' approach and assumes the effect of interferences on a particular analyte are not only linear, but additive, This approach was applied to samples,pith high concentrations of interferents and works well, providing acceptable estimates in 90% of analyte-interferent combinations (at 10% error tolerance). The emphasis of the discussion is placed on how well this system deals with 'problematic' samples, i.e. those samples where matrix effects cause considerable analytical error.
引用
收藏
页码:1307 / 1315
页数:9
相关论文
共 15 条
[1]   INTERFERENCE FROM EASILY IONIZABLE ELEMENT MATRICES IN INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY - A SPATIAL STUDY [J].
BLADES, MW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (09) :881-900
[2]   COMPARISON OF PATTERN-RECOGNITION TECHNIQUES FOR SAMPLE CLASSIFICATION USING ELEMENTAL COMPOSITION - APPLICATIONS FOR ICP-AES [J].
BRANAGH, W ;
YU, HN ;
SALIN, ED .
APPLIED SPECTROSCOPY, 1995, 49 (07) :964-970
[3]  
BRANAGH W, 1995, SPECTROSCOPY EUGENE, V10, P20
[4]   IMPROVED CALIBRATION FOR INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY USING GENERALIZED REGRESSION NEURAL NETWORKS [J].
CATASUS, M ;
BRANAGH, W ;
SALIN, ED .
APPLIED SPECTROSCOPY, 1995, 49 (06) :798-807
[5]  
DAHAI S, 1988, SPECTROCHIM ACTA B, V43, P391
[6]   EASILY IONIZABLE ELEMENT INTERFERENCES IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROSCOPY .1. EFFECT ON RADIAL ANALYTE EMISSION PATTERNS [J].
GALLEY, PJ ;
GLICK, M ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (6-7) :769-788
[7]  
KARANASSIOS V, 1995, 78 CAN SOC CHEM C EX
[8]   EXCITATION TEMPERATURE AND ANALYTICAL PARAMETERS FOR AN ETHANOL-LOADED INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION SPECTROMETER [J].
MCCRINDLE, RI ;
RADEMEYER, CJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (05) :399-404
[9]   A PREDICTIVE MODEL OF PLASMA MATRIX EFFECTS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
RAMSEY, MH ;
THOMPSON, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (03) :185-193
[10]  
SAGER M, 1991, ICP INFORM NEWSL, V17, P435