Hot water heat stores with stratification are a common technology used in solar energy systems and reuse of waste heat. Adding a PCM module at the top of the water tank would give the system higher storage density, and compensate heat loss in the top layer. The work presented here includes experimental results and numerical simulation of the system using an explicit finite-difference method. Experiments and simulations were carried out using different cylindrical PCM modules. With only 1/16 of the volume of the store being PCM, 3/16 of water at the top of the store was held warm for 50% to 200% longer and the average energy density was increased by 20% to 45%. Furthermore, these 3/16 of water were reheated by the heat from the module after being cooled down in only 20 min. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:699 / 711
页数:13
相关论文
共 19 条
[1]  
ABDOLLY MA, 1982, ENERGY CONVERSION MA, V23, P275
[2]   A numerical study for the prediction of turbulent mixing factor in thermal storage tanks [J].
Al-Najem, NM ;
El-Refaee, MM .
APPLIED THERMAL ENGINEERING, 1997, 17 (12) :1173-1181
[3]  
ALIYADEH S, 1999, SOL ENERGY, V66, P409
[4]   STRATIFICATION BEHAVIOR IN A CHILLED WATER STORAGE TANK [J].
ALMARAFIE, AMR .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1987, 10 (06) :364-366
[5]   A NUMERICAL STUDY OF TRANSIENT MIXED CONVECTION FLOWS IN A THERMAL STORAGE TANK [J].
CHAN, AMC ;
SMEREKA, PS ;
GIUSTI, D .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :246-253
[6]  
DAVIS ES, 1975, P WORKSH SOL EN STOR, V38
[7]  
FARLOW SJ, 1993, PARTIAL DIFFERENTIAL, P309
[8]  
Ghaddar NK, 1997, INT J ENERG RES, V21, P411, DOI 10.1002/(SICI)1099-114X(199704)21:5<411::AID-ER262>3.0.CO
[9]  
2-B
[10]  
MEHLING H, 2000, P IEA ECES IA ANN 10