BACKGROUND: Definitions of stent thrombosis that have been used in clinical trials of drug-eluting stents have been restrictive and have not been used in a uniform manner. METHODS: We applied a hierarchical classification of stent thrombosis set by the Academic Research Consortium (ARC) across randomized trials involving 878 patients treated with sirolimus-eluting stents, 1400 treated with paclitaxel-eluting stents, and 2267 treated with bare-metal stents. We then pooled 4 years of follow-up data. All events were adjudicated by an independent clinical-events committee. RESULTS: The cumulative incidence of stent thrombosis according to the original protocol definitions was 1.2% in the sirolimus-stent group versus 0.6% in the bare-metal-stent group (P=0.20; 95% confidence interval [CI], -0.4 to 1.5) and 1.3% in the paclitaxel-stent group versus 0.8% in the bare-metal-stent group (P=0.24; 95% CI, -0.3 to 1.4). The incidence of definite or probable stent thrombosis as defined by the ARC was 1.5% in the sirolimus-stent group versus 1.7% in the bare-metal-stent group (P=0.70; 95% CI, -1.5 to 1.0) and 1.8% in the paclitaxel-stent group versus 1.4% in the bare-metal-stent group (P=0.52; 95% CI, -0.7 to 1.4). The incidence of definite or probable events occurring 1 to 4 years after implantation was 0.9% in the sirolimus-stent group versus 0.4% in the bare-metal-stent group and 0.9% in the paclitaxel-stent group versus 0.6% in the bare-metal-stent group. CONCLUSIONS: The incidence of stent thrombosis did not differ significantly between patients with drug-eluting stents and those with bare-metal stents in randomized clinical trials, although the power to detect small differences in rates was limited.
引用
收藏
页码:1020 / 1029
页数:10
相关论文
共 30 条
[1]  
CAMENZIND E, 2006, SAFETY DRUG ELUTING
[2]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[3]  
Cutlip DE, 2001, CIRCULATION, V103, P1967
[4]  
DAEMEN J, IN PRESS LANCET
[5]   Clopidogrel use and long-term clinical outcomes after drug-eluting stent implantation [J].
Eisenstein, Eric L. ;
Anstrom, Kevin J. ;
Kong, David F. ;
Shaw, Linda K. ;
Tuttle, Robert H. ;
Mark, Daniel B. ;
Kramer, Judith M. ;
Harrington, Robert A. ;
Matchar, David B. ;
Kandzari, David E. ;
Peterson, Eric D. ;
Schulman, Kevin A. ;
Califf, Robert M. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 297 (02) :159-168
[6]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[7]  
Food and Drug Administration, CIRC SYST DEV PAN M
[8]   Six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions [J].
Grube, E ;
Silber, S ;
Hauptmann, KE ;
Mueller, R ;
Buellesfeld, L ;
Gerckens, U ;
Russell, ME .
CIRCULATION, 2003, 107 (01) :38-42
[9]   Sirolimus-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents - The SISR randomized trial [J].
Holmes, DR ;
Teirstein, P ;
Satler, L ;
Sketch, M ;
O'Malley, J ;
Popma, JJ ;
Kuntz, RE ;
Fitzgerald, PJ ;
Wang, H ;
Caramanica, E ;
Cohen, SA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (11) :1264-1273
[10]   Analysis of 1-year clinical outcomes in the SIRIUS trial - A randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis [J].
Holmes, DR ;
Leon, MB ;
Moses, JW ;
Popma, JJ ;
Cutlip, D ;
Fitzgerald, PJ ;
Brown, C ;
Fischell, T ;
Wong, SC ;
Midei, M ;
Snead, D ;
Kuntz, RE .
CIRCULATION, 2004, 109 (05) :634-640