A comparison of optical coherence tomography and retinal nerve fiber layer photography for detection of nerve fiber layer damage in glaucoma

被引:125
作者
Zangwill, LM [1 ]
Williams, J
Berry, CC
Knauer, S
Weinreb, RN
机构
[1] Univ Calif San Diego, Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Ophthalmol, Diagnost Imaging Lab, La Jolla, CA 92093 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1016/S0161-6420(00)00168-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness measurements with established methods for assessment of glaucomatous damage using RNFL photography and visual field testing. Design: Cross-sectional study. Participants: Fifty-eight eyes of 58 healthy volunteer ocular hypertensive patients, glaucoma suspect patients, and glaucoma patients were included. Methods: Optical coherence tomography 3.4-mm diameter circular scans were obtained within 3 months of RNFL photography and standard achromatic visual field testing. Three independent observers graded RNFL photographs using two standardized protocols. For each method, superior and inferior arcuate bundles were scored separately, and interobserver and intraobserver variation was measured. Standard achromatic visual field mean deviation in the superior and inferior hemifields was compared with RNFL damage as assessed by photography and OCT RNFL thickness measurements. Main Outcome Measures: Visual field mean deviation and severity of glaucomatous RNFL damage as assessed by photography. Results: Optical coherence tomography RNFL thickness decreased with increasing RNFL damage as assessed by photography using both methods of photographic assessment. Standard achromatic perimetry mean deviation was significantly associated with OCT RNFL thickness (R-2 35%-43%) and RNFL photography severity score (R-2 = 18%-29%). Conclusions: These results suggest that the OCT shows promise for providing quantitative measures of RNFL thickness for diagnosing and monitoring glaucoma. (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:1309 / 1315
页数:7
相关论文
共 21 条
[1]  
Bowd C, 2000, ARCH OPHTHALMOL-CHIC, V118, P22
[2]   CORRELATION OF VISUAL-FIELD WITH SCANNING CONFOCAL LASER OPTIC DISC MEASUREMENTS IN GLAUCOMA [J].
BRIGATTI, L ;
CAPRIOLI, J .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (09) :1191-1194
[3]  
Brigatti L, 1996, ARCH OPHTHALMOL-CHIC, V114, P424
[4]   OPTICAL BIOPSY AND IMAGING USING OPTICAL COHERENCE TOMOGRAPHY [J].
FUJIMOTO, JG ;
BREZINSKI, ME ;
TEARNEY, GJ ;
BOPPART, SA ;
BOUMA, B ;
HEE, MR ;
SOUTHERN, JF ;
SWANSON, EA .
NATURE MEDICINE, 1995, 1 (09) :970-972
[5]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[6]   Retinal nerve fiber layer assessment by scanning laser polarimetry and standardized photography [J].
Niessen, AGJE ;
vandenBerg, TJTP ;
Langerhorst, CT ;
Greve, EL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 121 (05) :484-493
[7]   GRADING OF RETINAL NERVE-FIBER LAYER WITH A PHOTOGRAPHIC REFERENCE SET [J].
NIESSEN, AGJE ;
VANDENBERG, TJTP ;
LANGERHORST, CT ;
BOSSUYT, PMM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 120 (05) :577-586
[8]  
PULIAFITO CA, 1995, OPHTHALMOLOGY, V102, P217
[9]  
QUIGLEY HA, 1980, ARCH OPHTHALMOL-CHIC, V98, P1564
[10]  
QUIGLEY HA, 1996, DIAGNOSING EARLY GLA, P23