A novel mesh electrode catheter for mapping and radiofrequency delivery at the left atrium-pulmonary vein junction: A single-catheter approach to pulmonary vein antrum isolation

被引:17
作者
Arruda, Mauricio S.
He, Ding Sheng
Friedman, Paul
Nakagawa, Hiroshi
Bruce, Charles
Azegami, Koji
Anders, Robert
Kozel, Peter
Chiavetta, Amedeo
Marad, Paul
Macadam, David
Jackman, Warren
Wilber, David J.
机构
[1] Cleveland Clin Fdn, Dept Cardiovasc Med, Electrophysiol Sect, Cleveland, OH 44195 USA
[2] Univ Arizona, Tucson, AZ USA
[3] Mayo Clin, Rochester, MN USA
[4] Bard Electrophysiol, Lowell, MA USA
[5] Univ Oklahoma, Oklahoma City, OK USA
[6] Loyola Univ, Chicago, IL 60611 USA
关键词
atrial fibrillation; catheter Ablation; AF ablation; pulmonary vein; multi electrode catheter;
D O I
10.1111/j.1540-8167.2007.00720.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A Single-Catheter for Mapping and Ablation of PV. Background: Electrical isolation of pulmonary veins (PV) by radiofrequency (RF) ablation is often performed in patients with atrial fibrillation (AF). Current catheter technology usually requires the use of a multielectrode catheter for mapping in addition to the ablation catheter. Purpose: We evaluated the feasibility and safety of using a single, expandable electrode catheter (MESH) to map and to electrically isolate the PV. Methods and Results: Nineteen closed-chest mongrel dogs, weighing 23-35 kg, were studied under general anesthesia. Intracardiac echocardiography (ICE) was used to guide transseptal puncture and to assess PV dimensions and contact of the MESH with PV ostia. ICE and angiography of RSPV were obtained before and after ablation, and prior to sacrifice at 7-99 days. An 11.5 Fr steerable MESH was advanced and deployed at the ostium of the RSPV. Recordings were obtained via the 36 electrodes comprising the MESH. For circumferential ablation, RF current was delivered at a target temperature of 62-65 degrees C (4 thermocouples) and maximum power of 70-100 W for 180 to 300 seconds. Each animal received 1-4 RF applications. Entrance conduction block was obtained in 13/19 treated RSPVs. Pathological examination confirmed circumferential and transmural lesions in 13 of 19 RSPV. LA mural thrombus was present in 3 animals. There was no significant PV stenosis. Conclusion: Based on this canine model, a new expandable MESH catheter may safely be used for mapping and for PV antrum isolation. This approach may decrease procedure time without compromising success rate in patients undergoing AF ablation.
引用
收藏
页码:206 / 211
页数:6
相关论文
共 32 条
[1]   Feasibility and safety of pulmonary vein isolation using a new mapping and navigation system in patients with refractory atrial fibrillation [J].
Arentz, T ;
von Rosenthal, J ;
Blum, T ;
Stockinger, J ;
Bürkle, G ;
Weber, R ;
Jander, N ;
Neumann, FJ ;
Kalusche, D .
CIRCULATION, 2003, 108 (20) :2484-2490
[2]   Effects of circumferential ostial radiofrequency lesions on pulmonary vein activation recorded with a multipolar basket catheter [J].
Arentz, T ;
Von Rosenthal, J ;
Weber, R ;
Bürkle, G ;
Blum, T ;
Stockinger, J ;
Neumann, FJ ;
Kalusche, D .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (03) :302-308
[3]  
ARRUDA MS, 2001, PACE, V24, P633
[4]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[5]   Laser ablation of the pulmonary veins by using a fiberoptic balloon catheter: Implications for treatment of paroxysmal atrial fibrillation [J].
Fried, NM ;
Tsitlik, A ;
Rent, KC ;
Berger, RD ;
Lardo, AC ;
Calkins, H ;
Halperin, HR .
LASERS IN SURGERY AND MEDICINE, 2001, 28 (03) :197-203
[6]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[7]   Prevalence of pulmonary vein disconnection after anatomical ablation for atrial fibrillation:: consequences of wide atrial encircling of the pulmonary veins [J].
Hocini, M ;
Sanders, P ;
Jaïs, P ;
Hsu, LF ;
Weerasoriya, R ;
Scavée, C ;
Takahashi, Y ;
Rotter, M ;
Raybaud, F ;
Macle, L ;
Clémenty, J ;
Haïssaguerre, M .
EUROPEAN HEART JOURNAL, 2005, 26 (07) :696-704
[8]   Transvenous catheter cryoablation for treatment of atrial fibrillation: Results of a feasibility study [J].
Hoyt, RH ;
Wood, M ;
Daoud, E ;
Feld, G ;
Sehra, R ;
Pelkey, W ;
Kay, GN ;
Calkins, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 :S78-S82
[9]   Empirical pulmonary vein isolation in patients with chronic atrial fibrillation using a three-dimensional nonfluoroscopic mapping system: Long-term follow-up [J].
Kanagaratnam, L ;
Tomassoni, G ;
Schweikert, R ;
Pavia, S ;
Bash, D ;
Beheiry, S ;
Lesh, M ;
Niebauer, M ;
Saliba, W ;
Chung, M ;
Tchou, P ;
Natale, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (12) :1774-1779
[10]   Fiberoptic balloon catheter ablation of pulmonary vein ostia in pigs using photonic energy delivery with diode laser [J].
Lemery, R ;
Veinot, JP ;
Tang, ASL ;
Green, M ;
Farr, N ;
Baxter, L ;
McIntyre, J ;
Sinofsky, E .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (01) :32-36