摘要
In electrospray ionization (ESI), droplets with a surface excess charge are created. The rate of production of surface excess charge is a constant and is equal to the rate of ion production. The ions appearing in the mass spectrum are postulated to be those that formed the surface excess charge at the time of droplet formation (or their collision products). An equilibrium model based on competition among the ions in the solution for the limited number of excess charge sites has been developed. This model accurately predicts the response curves of singly-charged ionic analytes as a function of the concentration of electrolyte and other analytes and provides an explanation for the selective effectiveness of ESI. At low concentrations of total analyte (micromolar and less), the response curves are linear, indifferent to the presence of other low concentration analytes, and suppressed by electrolyte concentrations in excess of the minimum required, At higher analyte concentrations, the response becomes independent of analyte concentration but highly affected by the presence of other analytes.
引用
收藏
页码:4885 / 4893
页数:9
相关论文
共 25 条
[1]
ALEKSANDROV ML, 1987, DOKL AKAD NAUK SSSR, V59, P2642
[2]
MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY - ELECTROSPRAY AS AN ELECTROLYSIS CELL [J].
BLADES, AT ;
IKONOMOU, MG ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2109-2114
[4]
WEIGHING NAKED PROTEINS - PRACTICAL, HIGH-ACCURACY MASS MEASUREMENT OF PEPTIDES AND PROTEINS [J].
CHAIT, BT ;
KENT, SBH .
SCIENCE, 1992, 257 (5078) :1885-1894
[5]
ELECTROSPRAY MASS-SPECTROMETRY - A STUDY ON SOME AQUEOUS-SOLUTIONS OF METAL-SALTS [J].
CHENG, ZL ;
SIU, KWM ;
GUEVREMONT, R ;
BERMAN, SS .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :281-288
[6]
Electrospray mass spectrometry applied inorganic and organometallic chemistry [J].
Colton, R ;
DAgostino, A ;
Traeger, JC .
MASS SPECTROMETRY REVIEWS, 1995, 14 (02) :79-106
[7]
MOLECULAR BEAMS OF MACROIONS [J].
DOLE, M ;
MACK, LL ;
HINES, RL .
JOURNAL OF CHEMICAL PHYSICS, 1968, 49 (05) :2240-&
[8]
ELECTROHYDRODYNAMIC ION-SOURCE FOR MASS-SPECTROMETRY OF LIQUIDS [J].
EVANS, CA ;
HENDRICKS, CD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (10) :1527-+
[9]
ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[10]
ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71