Flow-injection spectrophotometric determination of periodate and iodate by their reaction with pyrogallol red in acidic media

被引:19
作者
Ensafi, AA [1 ]
Chamjangali, MA [1 ]
机构
[1] Isfahan Univ Technol, Coll Chem, Esfahan 84156, Iran
关键词
periodate; iodate; flow-injection analysis; pyrogallol red; spectrophotometry;
D O I
10.1016/S1386-1425(02)00032-X
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple and efficient flow-injection method was used with good results to determine periodate and iodate in water. The-method is based on the reaction of periodate or iodate with pyrogallol red in sulfuric acid media. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of pyrogallol red at 470 nm. The chemical and FIA variables were established using the univariate and simplex optimization methods. The calibration curve was linear over the concentration ranges of 0.8-73.0 and 2.0-100.0 muM for IO4- and IO3-, respectively. The detection limits were 0.7 and 1.0 muM for IO4- and IO3-, respectively. The sample throughput was 20+/-5 h(-1). The influence of potential interfering ions in the determination of the anions was tested. The relative standard deviations for 4.20 and 5.73 muM periodate and iodate were 1.8 and 2.2%, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:2835 / 2839
页数:5
相关论文
共 19 条
[1]   Kinetic determination of periodate based on its reaction with ferroin and its application to the indirect determination of ethylene glycol and glycerol [J].
Afkhami, A ;
Mosaed, F .
MICROCHEMICAL JOURNAL, 2001, 68 (01) :35-40
[2]   Spectrophotometric determination of periodate and iodate by a differential kinetic method [J].
Afkhami, A ;
Zarei, AR .
TALANTA, 2001, 53 (04) :815-821
[4]   REVIEW - AMPLIFICATION REACTIONS - ORIGINS AND DEFINITIONS PROGRESS AND PRESENT STATUS [J].
BURNS, DT ;
TOWNSHEND, A .
TALANTA, 1992, 39 (07) :715-735
[5]  
CALLEJON M, 1986, MICROCHEM J, V34, P83
[6]   1,3-CYCLOPENTANEDIONE BIS(4-METHYLTHIOSEMICARBAZONE) MONOHYDROCHLORIDE AS A SPECTROPHOTOMETRIC REAGENT FOR THE DETERMINATION OF IODATE IN ACETIC AND PERCHLORIC-ACID MEDIA [J].
CEBA, MR ;
SANCHEZ, JCJ ;
DIAZ, TG .
MICROCHEMICAL JOURNAL, 1985, 31 (03) :256-260
[7]   Spectrophotometric determination of periodate or iodate ions by liquid-liquid extraction as an ion-pair using tetramethylammonium iodide [J].
ElShahawi, MS ;
AlHashemi, FA .
TALANTA, 1996, 43 (12) :2037-2043
[8]   IODOMETRIC DETERMINATION OF GOLD AND PLATINUM BY 168-FOLD AND 126-FOLD CHEMICAL AMPLIFICATION REACTIONS [J].
ELSHAHAWI, MS ;
FARAG, AB .
ANALYTICA CHIMICA ACTA, 1995, 307 (01) :139-144
[9]  
ELWAKIL AM, 1993, TALANTA, V401, P841
[10]   Flow-injection simultaneous determination of iodate and periodate by spectrophotometric and spectrofluorometric detection [J].
Ensafi, AA ;
Dehaghi, GB .
ANALYTICAL SCIENCES, 2000, 16 (01) :61-64