Empirical model for biofiltration of toluene

被引:24
作者
Strauss, JM [1 ]
du Plessis, CA [1 ]
Riedel, KHJ [1 ]
机构
[1] Univ Orange Free State, Dept Microbiol & Biochem, Sasol Ctr Biotechnol, ZA-9300 Bloemfontein, South Africa
来源
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE | 2000年 / 126卷 / 07期
关键词
D O I
10.1061/(ASCE)0733-9372(2000)126:7(644)
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
in this study the toluene removal efficiency of a composted pine bark biofilter was determined at loading rates ranging from 9.04 to 54.21 g m(-3) h(-1), retention times of 0.25-3.0 min, and at various bed heights. Toluene removal efficiencies exceeding 90% were obtained when the biofilter was subjected to a gas retention time in excess of 0.32 min (19.2 s) and loading rates below 42 g m(-3) h(-1). The data obtained were used to develop an empirical model. The empirical model successfully described the overall removal efficiency with an R-2 value of 0.98. The influence of oxygen concentration an the removal efficiency was also evaluated. Reduced biofilter performance was observed at oxygen concentrations below 5%. A wide range of microorganisms were isolated from the: biofilter, which included Corynebacterium jeikeium A, Corynebacterium nitrilophilus, Micrococcus luteus, Pseudomonas mendocina, Sphingobacterium thalphophilum, and Turicella oritidis.
引用
收藏
页码:644 / 648
页数:5
相关论文
共 20 条
[1]   Characterization of a biofilter treating toluene contaminated air [J].
Andreoni, V ;
Origgi, G ;
Colombo, M ;
Calcaterra, E ;
Colombi, A .
BIODEGRADATION, 1997, 7 (05) :397-404
[3]   Biological waste air treatment in biotrickling filters [J].
Cox, HHJ ;
Deshusses, MA .
CURRENT OPINION IN BIOTECHNOLOGY, 1998, 9 (03) :256-262
[4]  
du Plessis CA, 1998, BIOTECHNOL BIOENG, V58, P408, DOI 10.1002/(SICI)1097-0290(19980520)58:4<408::AID-BIT8>3.0.CO
[5]  
2-N
[6]  
FEIDIEKER D, 1994, FEMS MICROBIOL ECOL, V15, P265, DOI 10.1111/j.1574-6941.1994.tb00250.x
[7]   Kinetic behavior of the toluene biofiltration process [J].
Hwang, SJ ;
Tang, HM .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (06) :664-673
[8]  
KAPAHI R, 1995, BIOCYCLE, P87
[9]   BIOLOGICAL PURIFICATION OF EXHAUST AIR USING FIXED BACTERIAL MONOCULTURES [J].
KIRCHNER, K ;
SCHLACHTER, U ;
REHM, HJ .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1989, 31 (5-6) :629-632
[10]   Biofiltration for the removal and 'detoxification' of a complex mixture of volatile organic compounds [J].
Kleinheinz, GT ;
Bagley, ST .
JOURNAL OF INDUSTRIAL MICROBIOLOGY & BIOTECHNOLOGY, 1998, 20 (02) :101-108