The MFI-UF as a water quality test and monitor

被引:100
作者
Boerlage, SFE
Kennedy, MD
Aniye, MP
Abogrean, E
Tarawneh, ZS
Schippers, JC
机构
[1] Burns & Roe Worley Pty Ltd, Perth, WA 6000, Australia
[2] Int Inst Infrastruct Hydraul & Environm Engn IHE, NL-2601 DA Delft, Netherlands
[3] Kiwa Res & Consultancy, NL-3430 BB Nieuwegein, Netherlands
关键词
modified fouling index; MFI-UF; particulate fouling; cake filtration; temperature and pressure dependency; cake compression;
D O I
10.1016/S0376-7388(02)00427-1
中图分类号
TQ [化学工业];
学科分类号
0817 [化学工程与技术];
摘要
The MFI0.45 test to measure the particulate fouling potential of feedwater, was recently extended to incorporate smaller particles using a polyacrylonitrile, 13 kDa (PAN 13 kDa) ultrafiltration membrane (MFI-UF). This study investigates various aspects of the new MFI-UF test to establish its general use for measuring the particulate fouling potential of feedwater; namely (i) proof of cake filtration via stability of the MFI-UF over time and linearity of the index with particulate concentration, (ii) reproducibility of the MFI-UF with PAN 13 kDa membrane manufacture and membrane reuse, (iii) the temperature and pressure dependency of the MFI-UF. The aforementioned aspects were examined using low (e.g. tap water) and high fouling feedwater (e.g. diluted canal water). Cake filtration was demonstrated for all feedwater tested. The MFI-UF was stable over time and proportional to particulate concentration. Reproducibility of the MFI-UF was found for 83% of the membranes tested and in five tests using one membrane, applying chemical cleaning in between. Correction to the reference temperature (20 degreesC) of the MFI-UF test required only correction of feedwater viscosity. However, compression of the cake with increasing pressure was demonstrated for all feedwater. Therefore, compressibility coefficients were determined for a given feedwater and a global compressibility coefficient was calculated for correction to the reference pressure (2 bar) of the MFI-UF test. Application of the MFI-UF as a continuous monitor of feedwater quality was trialed and requires further investigation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 289
页数:19
相关论文
共 15 条
[1]
BANDA H, 1987, AUFBEREITUNGS TECHNI, V9, P513
[2]
The modified fouling index using ultrafiltration membranes (MFI-UF): characterisation, filtration mechanisms and proposed reference membrane [J].
Boerlage, SFE ;
Kennedy, MD ;
Dickson, MR ;
El-Hodali, DEY ;
Schippers, JC .
JOURNAL OF MEMBRANE SCIENCE, 2002, 197 (1-2) :1-21
[3]
Carman P. C., 1937, T I CHEM ENG-LOND, V15, P150, DOI [10.1016/S0263-8762(97)80003-2, DOI 10.1016/S0263-8762(97)80003-2]
[4]
Carman P.C., 1938, T I CHEM ENG-LOND, V16, P168
[5]
Existence of critical recovery and impacts of operational mode on potable water microfiltration [J].
Chellam, S ;
Jacangelo, JG .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 1998, 124 (12) :1211-1219
[6]
HEERTJES PM, 1964, T I CHEM ENG-LOND, V42, P266
[7]
Water permeability in ultrafiltration and microfiltration: Viscous and electroviscous effects [J].
Huisman, IH ;
Dutre, B ;
Persson, KM ;
Tragardh, G .
DESALINATION, 1997, 113 (01) :95-103
[8]
EFFECTS OF SIZE AND COMPRESSIBILITY OF SUSPENDED PARTICLES AND SURFACE PORE-SIZE OF MEMBRANE ON FLUX IN CROSS-FLOW FILTRATION [J].
KAWAKATSU, T ;
NAKAO, S ;
KIMURA, S .
JOURNAL OF MEMBRANE SCIENCE, 1993, 81 (1-2) :173-190
[9]
LEWIS WK, 1912, J IND ENG CHEM, V4, P528
[10]
STUDY OF MEMBRANE COMPACTION AND ITS INFLUENCE ON ULTRAFILTRATION WATER PERMEABILITY [J].
PERSSON, KM ;
GEKAS, V ;
TRAGARDH, G .
JOURNAL OF MEMBRANE SCIENCE, 1995, 100 (02) :155-162