Liquid nitrogen freezers: A potential source of microbial contamination of hematopoietic stem cell components

被引:132
作者
Fountain, D
Ralston, M
Higgins, N
Gorlin, JB
Uhl, L
Wheeler, C
Antin, JH
Churchill, WH
Benjamin, RJ
机构
[1] BRIGHAM & WOMENS HOSP,DEPT PATHOL,BOSTON,MA 02115
[2] BRIGHAM & WOMENS HOSP,BLOOD BANK,BOSTON,MA 02115
[3] BETH ISRAEL DEACONESS MED CTR,BLOOD BANK,BOSTON,MA
[4] BETH ISRAEL DEACONESS MED CTR,DEPT HEMATOL ONCOL,BOSTON,MA
[5] CHILDRENS HOSP,MED CTR,BLOOD BANK,BOSTON,MA 02115
关键词
D O I
10.1046/j.1537-2995.1997.37697335152.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The recent report of hepatitis B transmission between hematopoietic progenitor and putative stem cell (HPC) components stored in liquid nitrogen led to the questioning of whether evidence existed for similar contamination by bacterial or fungal elements. STUDY DESIGN AND METHODS: Microbial contamination rates were reviewed for 704 HPC components from 255 patients over an 18-month period. Five liquid nitrogen freezers were surveyed for microbial contamination. The literature was reviewed to ascertain the published experience of other laboratories with HPC component contamination first documented on thawing. RESULTS: Seven (1.2%) of 583 thawed components were found to be contaminated with a variety of environmental or waterborne organisms, despite a meticulous protocol to prevent contamination during thawing. AU of. these components had been sterile on cryopreservation. Literature review revealed a similar incidence of postthaw contamination from other centers. Microbial survey of liquid nitrogen freezers revealed low-level contamination in four of five. The organisms represented were similar to those cultured from thawed HPC components. One freezer was heavily contaminated by Aspergillus species. CONCLUSION: Liquid nitrogen freezers are not sterile, and both the liquid and vapor phases are potential sources of microbial contamination of HFC components. While low-level contamination by environmental organisms may be common, the occurrence of heavy contamination by potential pathogens such as Aspergillus species suggests that monitoring of liquid nitrogen sterility may be indicated. Strategies to assess and prevent microbial transmission from liquid nitrogen tb HPC components need further development.
引用
收藏
页码:585 / 591
页数:7
相关论文
共 12 条
[1]   STRATEGIES FOR THE AVOIDANCE OF BACTERIAL-CONTAMINATION OF BLOOD COMPONENTS [J].
BARRETT, BB ;
ANDERSEN, JW ;
ANDERSON, KC .
TRANSFUSION, 1993, 33 (03) :228-233
[2]  
D'Antonio D, 1991, Haematologica, V76 Suppl 1, P44
[3]  
*FDN ACCR HEM CELL, 1996, STAND HEM PROG CELL
[4]  
KLEIN HG, 1996, STANDARDS BLOOD BANK, P59
[5]  
LAZARUS HM, 1991, BONE MARROW TRANSPL, V7, P241
[6]   Bacterial contamination rates following processing of bone marrow and peripheral blood progenitor cell preparations [J].
Padley, D ;
Koontz, F ;
Trigg, ME ;
Gingrich, R ;
Strauss, RG .
TRANSFUSION, 1996, 36 (01) :53-56
[7]  
PRINCE HM, 1995, BONE MARROW TRANSPL, V15, P87
[8]   BACTERIAL-CONTAMINATION OF BONE-MARROW GRAFTS INTENDED FOR AUTOLOGOUS AND ALLOGENEIC BONE-MARROW TRANSPLANTATION - INCIDENCE AND CLINICAL-SIGNIFICANCE [J].
ROWLEY, SD ;
DAVIS, J ;
DICK, J ;
BRAINE, HG ;
CHARACHE, P ;
SARAL, R ;
SENSENBRENNER, LL ;
SANTOS, GW .
TRANSFUSION, 1988, 28 (02) :109-112
[9]   MICROBIOLOGIC CONTAMINATION OF PERIPHERAL-BLOOD STEM-CELL AUTOGRAFTS [J].
SCHWELLA, N ;
ZIMMERMANN, R ;
HEUFT, HG ;
BLASCZYK, R ;
BEYER, J ;
RICK, O ;
KREISSIG, C ;
ZINGSEM, J ;
ECKSTEIN, R ;
SIEGERT, W .
VOX SANGUINIS, 1994, 67 (01) :32-35
[10]   ADVERSE REACTIONS IN PATIENTS TRANSFUSED WITH CRYOPRESERVED MARROW [J].
STRONCEK, DF ;
FAUTSCH, SK ;
LASKY, LC ;
HURD, DD ;
RAMSAY, NKC ;
MCCULLOUGH, J .
TRANSFUSION, 1991, 31 (06) :521-526