Robust Water/Fat Separation in the Presence of Large Field Inhomogeneities Using a Graph Cut Algorithm

被引:285
作者
Hernando, Diego [1 ,2 ]
Kellman, P. [3 ]
Haldar, J. P. [1 ,2 ]
Liang, Z-P. [1 ,2 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[3] NHLBI, Cardiac Energet Lab, NIH, Dept Hlth & Human Serv, Bethesda, MD 20892 USA
关键词
water/fat; graph cut; field map; cardiac MRI; Dixon; FAT DECOMPOSITION; DIXON TECHNIQUE; MAP ESTIMATION; RECONSTRUCTION; SEARCH;
D O I
10.1002/mrm.22177
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Water/fat separation is a classical problem for in vivo proton MRI. Although many methods have been proposed to address this problem, robust water/fat separation remains a challenge, especially in the presence of large amplitude of static field inhomogeneities. This problem is challenging because of the nonuniqueness of the solution for an isolated voxel. This paper tackles the problem using a statistically motivated formulation that jointly estimates the complete field map and the entire water/fat images. This formulation results in a difficult optimization problem that is solved effectively using a novel graph cut algorithm, based on an iterative process where all voxels are updated simultaneously. The proposed method has good theoretical properties, as well as an efficient implementation. Simulations and in vivo results are shown to highlight the properties of the proposed method and compare it to previous approaches. Twenty-five cardiac datasets acquired on a short, wide-bore scanner with different slice orientations were used to test the proposed method, which produced robust water/fat separation for these challenging datasets. This paper also shows example applications of the proposed method, such as the characterization of intramyocardial fat. Magn Reson Med 63:79-90, 2010. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:79 / 90
页数:12
相关论文
共 47 条
[1]
A survey of very large-scale neighborhood search techniques [J].
Ahuja, RK ;
Ergun, Ö ;
Orlin, JB ;
Punnen, AP .
DISCRETE APPLIED MATHEMATICS, 2002, 123 (1-3) :75-102
[2]
Chemical shift imaging with spectrum modeling [J].
An, L ;
Xiang, QS .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :126-130
[3]
[Anonymous], 1999, THESIS CORNELL U
[4]
Atalay MK, 2001, MAGNET RESON MED, V45, P341, DOI 10.1002/1522-2594(200102)45:2<341::AID-MRM1043>3.0.CO
[5]
2-Q
[6]
Bernstein MA., 2004, HDB MRI PULSE SEQUEN
[7]
Phase unwrapping via graph cuts [J].
Bioucas-Dias, Jose M. ;
Valadao, Goncalo .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2007, 16 (03) :698-709
[8]
Boyd S.P, 2004, Convex optimization, DOI [DOI 10.1017/CBO9780511804441, 10.1017/CBO9780511804441]
[9]
Boykov Y, 2006, HANDBOOK OF MATHEMATICAL MODELS IN COMPUTER VISION, P79, DOI 10.1007/0-387-28831-7_5
[10]
Fast approximate energy minimization via graph cuts [J].
Boykov, Y ;
Veksler, O ;
Zabih, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2001, 23 (11) :1222-1239