Magnetophoretic immunoassay of allergen-specific IgE in an enhanced magnetic field gradient

被引:68
作者
Hahn, Young Ki
Jin, Zongwen
Kang, Joo H.
Oh, Eunkeu
Han, Min-Kyu
Kim, Hak-Sung [1 ]
Jang, Jung-Tak
Lee, Jae-Hyun
Cheon, Jinwoo
Kim, Seung Hyun
Park, Hae-Sim
Park, Je-Kyun
机构
[1] Korea Adv Inst Sci & Technol, Dept Biosyst, Taejon 305701, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Biol Sci, Taejon 305701, South Korea
[3] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
[4] Ajou Univ, Sch Med, Dept Allergy & Clin Immunol, Suwon 442749, South Korea
关键词
D O I
10.1021/ac061522l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We demonstrate a novel magnetophoretic immunoassay of allergen-specific immunoglobulin E (IgE) based on the magnetophoretic deflection velocity of a microbead that is proportional to the associated magnetic nanoparticles under enhanced magnetic field gradient in a microchannel. In this detection scheme, two types of house dust mites, Dermatophagoides farinae (D. farinae) and Dermatophagoides pteronyssinus (D. pteronyssinus), were used as the model allergens. Polystyrene microbeads were conjugated with each of the mite extracts followed by incubation with serum samples. The resulting mixture was then reacted with magnetic nanoparticle-conjugated anti-human IgE for detection of allergen-specific IgE by using sandwich immuno-reactions. A ferromagnetic microstructure combined with a permanent magnet was employed to increase the magnetic field gradient (similar to 10(4) T/m) in a microfluidic device. The magnetophoretic velocities of microbeads were measured in a microchannel under applied magnetic field, and the averaged velocity was well correlated with the concentration of allergen-specific IgE in serum. From the analysis of pooled sera obtained from 44 patients, the detection limits of the allergen-specific human IgEs for D. farinae and D. pteronyssinus were determined to be 565 (0.045 IU/mL) and 268 fM (0.021 IU/mL), respectively. These values are 1 order of magnitude lower than those by a conventional CAP system. For evaluation of reproducibility and accuracy, unknown sera were subjected to a blind test by using the developed assay system, and they were compared with the CAP system. As a result, coefficient of variance was less than 10%, and the developed method enabled a fast assay with a tiny amount of serum (similar to 10 mu L).
引用
收藏
页码:2214 / 2220
页数:7
相关论文
共 43 条
[1]   An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities [J].
Choi, JW ;
Oh, KW ;
Thomas, JH ;
Heineman, WR ;
Halsall, HB ;
Nevin, JH ;
Helmicki, AJ ;
Henderson, HT ;
Ahn, CH .
LAB ON A CHIP, 2002, 2 (01) :27-30
[2]   DESIGNING HGMS MATRIX ARRAYS FOR SELECTIVE FILTRATION [J].
DELATOUR, C ;
SCHMITZ, G ;
MAXWELL, E ;
KELLAND, D .
IEEE TRANSACTIONS ON MAGNETICS, 1983, 19 (05) :2127-2129
[3]   Manipulation of magnetic microbeads in suspension using micromagnetic systems fabricated with soft lithography [J].
Deng, T ;
Whitesides, GM ;
Radhakrishnan, M ;
Zabow, G ;
Prentiss, M .
APPLIED PHYSICS LETTERS, 2001, 78 (12) :1775-1777
[4]   MAGNETIC SEPARATION IN BIOTECHNOLOGY. [J].
Dunlop, E.H. ;
Feiler, W.A. ;
Mattione, M.J. .
Biotechnology Advances, 1984, 2 (01) :63-74
[5]   The BARC biosensor applied to the detection of biological warfare agents [J].
Edelstein, RL ;
Tamanaha, CR ;
Sheehan, PE ;
Miller, MM ;
Baselt, DR ;
Whitman, LJ ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :805-813
[6]   Biological immunoassay utilizing magnetic marker and high Tc superconducting quantum interference device magnetometer [J].
Enpuku, K ;
Kuroda, D ;
Ohba, A ;
Yang, TQ ;
Yoshinaga, K ;
Nakahara, T ;
Kuma, H ;
Hamasaki, N .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2003, 42 (12A) :L1436-L1438
[7]   Detection of magnetic nanoparticles with superconducting quantum interference device (SQUID) magnetometer and application to immunoassays [J].
Enpuku, K ;
Minotani, T ;
Gima, T ;
Kuroki, Y ;
Itoh, Y ;
Yamashita, M ;
Katakura, Y ;
Kuhara, S .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1999, 38 (10A) :L1102-L1105
[8]   Microarrays for the screening of allergen-specific IgE in human serum [J].
Fall, BI ;
Eberlein-König, B ;
Behrendt, H ;
Niessner, R ;
Ring, J ;
Weller, MG .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :556-562
[9]   Dynamic DNA hybridization on a chip using paramagnetic beads [J].
Fan, ZH ;
Mangru, S ;
Granzow, R ;
Heaney, P ;
Ho, W ;
Dong, QP ;
Kumar, R .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4851-4859
[10]   Magnetoresistive-based biosensors and biochips [J].
Graham, DL ;
Ferreira, HA ;
Freitas, PP .
TRENDS IN BIOTECHNOLOGY, 2004, 22 (09) :455-462