Detection of Plasmodium vivax infection in the Republic of Korea by loop-mediated isothermal amplification (LAMP)

被引:33
作者
Chen, Jun-Hu [1 ,2 ]
Lu, Feng [1 ,3 ]
Lim, Chae Seung [4 ]
Kim, Jung-Yeon [5 ]
Ahn, Heui-June [6 ]
Suh, In-Bum [7 ]
Takeo, Satoru [8 ,9 ]
Tsuboi, Takafumi [8 ,9 ]
Sattabongkot, Jetsumon [10 ]
Han, Eun-Taek [1 ]
机构
[1] Kangwon Natl Univ, Coll Med, Dept Parasitol, Chunchon 200701, Gangwon Do, South Korea
[2] Zhejiang Acad Med Sci, Inst Parasit Dis, Hangzhou 310013, Peoples R China
[3] Jiangsu Inst Parasit Dis, Wuxi 214064, Peoples R China
[4] Korea Univ, Coll Med, Dept Lab Med, Seoul 425707, South Korea
[5] KCDC, Natl Inst Hlth, Dept Malaria & Parasit Dis, Seoul 122701, South Korea
[6] Korea Inst Radiol & Med Sci, Dept Internal Med, Seoul 139706, South Korea
[7] Kangwon Natl Univ, Coll Med, Dept Lab Med, Chunchon 200701, South Korea
[8] Ehime Univ, Venture Business Lab, Matsuyama, Ehime 7908577, Japan
[9] Ehime Univ, Cell Free Sci & Technol Res Ctr, Matsuyama, Ehime 7908577, Japan
[10] Armed Forces Res Inst Med Sci, Dept Entomol, Bangkok 10400, Thailand
关键词
Malaria; Plasmodium vivax; LAMP; Diagnosis; Republic of Korea; MALARIA; DIAGNOSIS; FALCIPARUM; TESTS; PCR; PARASITES;
D O I
10.1016/j.actatropica.2009.09.007
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Loop-mediated isothermal amplification (LAMP) is a novel technique that rapidly amplifies target DNA in isothermal conditions. In a previous study, the sensitivities and specificities of LAMP microscopy, and nested PCR were compared in the context of rapid malaria detection. In the present study, LAMP detected vivax malaria parasites in 115 of 117 microscopically positive samples (sensitivity, 98.3%; 95% CI, 97.4-100%), which agreed well with the nested PCR results (sensitivity, 99.1%; 95% CI: 96.0-100%). No positive cases of malaria were detected by LAMP or nested PCR in 50 consecutive feverish patients other than malaria from malaria endemic areas. LAMP performed on DNA extracted from heat-treated blood had a sensitivity of 93.3% (28/30, 95% CI: 84.4-100%) and specificity of 100% (30/30, 95% CI: 100%). The present study shows that LAMP based assays have high sensitivity specificity and amplification efficiencies for Plasmodium vivax detection. The authors recommend that LAMP can be considered as a rapid nucleic acid amplification assay for the molecular diagnosis of P. vivax in both clinical laboratories and malaria clinics in areas where vivax malaria is endemic. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 21 条
[1]   Purification and characterization of PCR-inhibitory components in blood cells [J].
Abu al-Soud, W ;
Rådström, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (02) :485-493
[2]  
Banoo S, 2006, NAT REV MICROBIOL, pS21, DOI [10.1038/nrmico1523, 10.1038/nrmicro1523]
[3]  
Bell D, 2006, NAT REV MICROBIOL, pS34, DOI [10.1038/nrmico1524, 10.1038/nrmicro1524]
[4]   Detection of four Plasmodium species by genus- and species-specific loop-mediated isothermal amplification for clinical diagnosis [J].
Han, Eun-Taek ;
Watanabe, Risa ;
Sattabongkot, Jetsumon ;
Khuntirat, Benjawan ;
Sirichaisinthop, Jeeraphat ;
Iriko, Hideyuki ;
Jin, Ling ;
Takeo, Satoru ;
Tsuboi, Takafumi .
JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (08) :2521-2528
[5]   How useful is PCR in the diagnosis of malaria? [J].
Hänscheid, T ;
Grobusch, MP .
TRENDS IN PARASITOLOGY, 2002, 18 (09) :395-398
[6]   Molecular evidence of infections with Babesia gibsoni parasites in Japan and evaluation of the diagnostic potential of a loop-mediated isothermal amplification method [J].
Ikadai, H ;
Tanaka, H ;
Shibahara, N ;
Matsuu, A ;
Uechi, M ;
Itoh, N ;
Oshiro, S ;
Kudo, N ;
Igarashi, I ;
Oyamada, T .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (06) :2465-2469
[7]   Loop-mediated isothermal amplification for detection of African trypanosomes [J].
Kuboki, N ;
Inoue, N ;
Sakurai, T ;
Di Cello, F ;
Grab, DJ ;
Suzuki, H ;
Sugimoto, C ;
Igarashi, I .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (12) :5517-5524
[8]   Is molecular biology the best alternative for diagnosis of malaria to microscopy? A comparison between microscopy, antigen detection and molecular tests in rural Kenya and urban Tanzania [J].
Mens, P. ;
Spieker, N. ;
Omar, S. ;
Heijnen, M. ;
Schallig, H. ;
Kager, P. A. .
TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2007, 12 (02) :238-244
[9]   Trial of the ParaSight-F test for malaria diagnosis in the primary health care system, Zimbabwe [J].
Mharakurwa, S ;
Manyame, B ;
Shiff, CJ .
TROPICAL MEDICINE & INTERNATIONAL HEALTH, 1997, 2 (06) :544-550
[10]   Rapid diagnostic tests for malaria parasites [J].
Moody, A .
CLINICAL MICROBIOLOGY REVIEWS, 2002, 15 (01) :66-+