Peptide-nucleic acid-modified ion-sensitive field-effect transistor-based biosensor for direct detection of DNA hybridization

被引:76
作者
Uno, Takeshi [1 ]
Tabata, Hitoshi [1 ]
Kawai, Tomoji [1 ]
机构
[1] Osaka Univ, Inst Sci & Ind Res, Osaka 5670047, Japan
关键词
D O I
10.1021/ac060273y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here, we report the development of a peptide-nucleic acid (PNA)-modified ion-sensitive field-effect transistor (IS-FET)-based biosensor that takes advantage of the change in the surface potential upon hybridization of a negatively charged DNA. PNA was immobilized on a silicon nitride gate insulator by an addition reaction between a maleimide group introduced on the gate surface, the succinimide group of N-(6-maleimidocaproyloxy) succinimide, and the thiol group of the terminal cysteine in PNA. The surface was characterized after each step of the reaction by X-ray photoelectron spectroscopy analysis, and the kinetic analysis of the hybridization events was assessed by surface plasmon resonance. In addition, we measured the zeta-potential before and after PNA-DNA hybridization in the presence of counterions to investigate the change in surface charge density at the surface-solution interface within the order of the Debye length. On the basis of the zeta-potential, the surface charge density, Delta Q, calculated using the Grahame equation was approximately 4.0 x 10(-3) C/m(2) and the estimated number of hybridized molecules was at least 1.7 x 10(11)/cm(2). The I-V characteristics revealed that the PNA-DNA duplexes induce a positive shift in the threshold voltage, V-T, and a decrease in the saturated drain current, I-D. These results demonstrate that direct detection of DNA hybridization should be possible using a PNA-modified IS-FET-based biosensor. PNA is particularly advantageous for this system because it enables highly specific and selective binding at low ionic strength.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 56 条
[1]   Trace analysis of an oligonucleotide with a specific sequence using PNA-based ion-channel sensors [J].
Aoki, H ;
Umezawa, Y .
ANALYST, 2003, 128 (06) :681-685
[2]  
Aoki H, 2000, ELECTROANAL, V12, P1272, DOI 10.1002/1521-4109(200011)12:16<1272::AID-ELAN1272>3.0.CO
[3]  
2-F
[4]  
Aoki H, 2002, ELECTROANAL, V14, P1405, DOI 10.1002/1521-4109(200211)14:19/20<1405::AID-ELAN1405>3.0.CO
[5]  
2-G
[6]   A CRITICAL-EVALUATION OF DIRECT ELECTRICAL PROTEIN-DETECTION METHODS [J].
BERGVELD, P .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) :55-72
[7]   The future of biosensors [J].
Bergveld, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1996, 56 (1-2) :65-73
[8]   A DNA diagnostic biosensor: development, characterisation and performance [J].
Berney, H ;
West, J ;
Haefele, E ;
Alderman, J ;
Lane, W ;
Collins, JK .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) :100-108
[9]   Synthesis of a stable and specific surface plasmon resonance biosensor surface employing covalently immobilized peptide nucleic acids [J].
Burgener, M ;
Sänger, M ;
Candrian, U .
BIOCONJUGATE CHEMISTRY, 2000, 11 (06) :749-754
[10]   Analysis of various sequence-specific triplexes by electron and atomic force microscopies [J].
Cherny, DI ;
Fourcade, A ;
Svinarchuk, F ;
Nielsen, PE ;
Malvy, C ;
Delain, E .
BIOPHYSICAL JOURNAL, 1998, 74 (02) :1015-1023