Evaluation of brain oxygenation during selective cerebral perfusion by near-infrared spectroscopy

被引:13
作者
Katoh, T [1 ]
Esato, K [1 ]
Gohra, H [1 ]
Hamano, K [1 ]
Fujimura, Y [1 ]
Zempo, N [1 ]
Nakashima, K [1 ]
Maekawa, T [1 ]
机构
[1] YAMAGUCHI UNIV,SCH MED,CRIT CARE MED CTR,UBE,YAMAGUCHI 755,JAPAN
关键词
D O I
10.1016/S0003-4975(97)00520-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Although selective cerebral perfusion (SCP) has been used for cerebral protection in aortic arch operations, the appropriate perfusion conditions of SCP are unclear. Methods. We used near-infrared spectroscopy, which evaluates brain ischemia noninvasively and continuously, to determine whether perfusion with SCP (core temperature, 20 degrees C; flow rate, 10 mL.kg(-1).min(-1)) was acceptable in terms of oxyhemoglobin and deoxyhemoglobin in patients having SCP for aortic arch operations (SCP group, n = 6) versus patients having cardiopulmonary bypass (CPB) for coronary artery bypass grafting (CPB group, n = 6). Results. There were no significant differences in age (65 +/- 10 versus 63 +/- 12 years), CPB time (199 +/- 67 versus 199 +/- 52 minutes), changes in hematocrit (-12.9% +/- 3.7% versus -12.5% +/- 6.0%), lowest blood pressure (43 +/- 7 versus 45 +/- 10 mm Hg), or highest central venous pressure (8 +/- 2 versus 9 +/- 4 mm Hg) between the SCP and CPB groups. In the SCP group, the maximum decrease in oxyhemoglobin level and the maximum increase in deoxyhemoglobin level were -5.0 to -11.4 mu mol/L and -0.1 to 3.9 mu mol/L, respectively; in the CPB group, the respective changes were -3.2 to -14.2 mu mol/l and -0.4 to 3.6 mu mol/L. Changes of oxyhemoglobin and deoxyhemoglobin levels in the SCP group were almost within the range of those in the CPB group. There were no brain complications in either group. Conclusions. As described here, SCP is acceptable and safe for brain protection in aortic arch procedures. (C) 1997 by The Society of Thoracic Surgeons.
引用
收藏
页码:432 / 436
页数:5
相关论文
共 22 条
[1]   CEREBRAL OXYGEN-METABOLISM DURING HYPOTHERMIC CIRCULATORY ARREST IN HUMANS [J].
AUSMAN, JI ;
MCCORMICK, PW ;
STEWART, M ;
LEWIS, G ;
DUJOVNY, M ;
BALAKRISHNAN, G ;
MALIK, GM ;
GHALY, RF .
JOURNAL OF NEUROSURGERY, 1993, 79 (06) :810-815
[2]  
Bloodwell R D, 1968, Ann Thorac Surg, V5, P236
[3]   RETROGRADE CEREBRAL PERFUSION VIA A SUPERIOR VENA-CAVAL CANNULA FOR AORTIC-ARCH ANEURYSM OPERATIONS [J].
COSELLI, JS .
ANNALS OF THORACIC SURGERY, 1994, 57 (06) :1668-1669
[4]  
CROUGHWELL N, 1992, J THORAC CARDIOV SUR, V103, P549
[5]   Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry [J].
Daubeney, PEF ;
Pilkington, SN ;
Janke, E ;
Charlton, GA ;
Smith, DC ;
Webber, SA .
ANNALS OF THORACIC SURGERY, 1996, 61 (03) :930-934
[6]  
FOX LS, 1982, J THORAC CARDIOV SUR, V83, P239
[7]   A RECONSIDERATION OF CEREBRAL PERFUSION IN AORTIC-ARCH REPLACEMENT [J].
FRIST, WH ;
BALDWIN, JC ;
STARNES, VA ;
STINSON, EB ;
OYER, PE ;
MILLER, DC ;
JAMIESON, SW ;
MITCHELL, RS ;
SHUMWAY, NE .
ANNALS OF THORACIC SURGERY, 1986, 42 (03) :273-281
[8]   FACTORS AND THEIR INFLUENCE ON REGIONAL CEREBRAL BLOOD-FLOW DURING NONPULSATILE CARDIOPULMONARY BYPASS [J].
GOVIER, AV ;
REVES, JG ;
MCKAY, RD ;
KARP, RB ;
ZORN, GL ;
MORAWETZ, RB ;
SMITH, LR ;
ADAMS, M ;
FREEMAN, AM .
ANNALS OF THORACIC SURGERY, 1984, 38 (06) :592-600
[9]  
GRIEPP RB, 1975, J THORAC CARDIOV SUR, V70, P1051
[10]   OXYGEN DELIVERY AND UTILIZATION IN HYPOTHERMIC DOGS [J].
GUTIERREZ, G ;
WARLEY, AR ;
DANTZKER, DR .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (03) :751-757