Reproducibility of volumetric quantification in intravascular ultrasound images

被引:20
作者
Hagenaars, T
Gussenhoven, EJ
van Essen, JA
Seelen, J
Honkoop, J
van der Lugt, A
机构
[1] Erasmus MC, Dept Cardiol, NL-3015 GE Rotterdam, Netherlands
[2] Erasmus MC, Dept Radiol, NL-3015 GE Rotterdam, Netherlands
[3] Twee Steden Hosp, Tilburg, Netherlands
[4] Interuniv Cardiol Inst, Utrecht, Netherlands
关键词
intravascular ultrasound; automated contour detection; volume; peripheral arteries; atherosclerosis; progression/regression;
D O I
10.1016/S0301-5629(99)00141-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The reproducibility of volume measurements in intravascular ultrasound (IVUS) images derived from separate pull-back manoeuvres remains to be elucidated. Patients (n = 23) were imaged with IVUS prior to (first series) and following percutaneous transluminal angiloplasty (PTA) (second series). In 15 patients, one matched vascular segment (3-4 cm in length), not subjected to PTA, was used for analysis of lumen, vessel and plaque volume using an automated contour analysis system. Volume measurements assessed by two independent observers and in the two separate series were compared. Interobserver differences in volume measurements were small (less than or equal to 0.4%), with low coefficients of variation (I 1.7%) and high correlation coefficients (r = 1.00). Differences in volume measurements obtained in the two separate series were small (less than or equal to 2.6%), with low coefficients of variation (less than or equal to 8.6%) and high correlation coefficients (r = 0.97-0.99), In conclusion, volume measurements derived from IVUS images are highly reproducible. Therefore, IVUS may be used to monitor the progression/regressionof atherosclerotic plaque volume in a longitudinal study. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:367 / 374
页数:8
相关论文
共 27 条
[1]   EFFECT OF PRAVASTATIN ON PROGRESSION AND REGRESSION OF CORONARY ATHEROSCLEROSIS AND VESSEL WALL CHANGES IN CAROTID AND FEMORAL ARTERIES - A REPORT FROM THE REGRESSION GROWTH EVALUATION STATIN STUDY [J].
DEGROOT, E ;
JUKEMA, JW ;
VANBOVEN, AJ ;
REIBER, JHC ;
ZWINDERMAN, AH ;
LIE, KI ;
ACKERSTAFF, RA ;
BRUSCHKE, AVG .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (09) :C40-C46
[2]   ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[3]  
GUSSENHOVEN EJ, 1993, DEV CARDIOVASC MED, V143, P157
[4]   CAN INTRACORONARY ULTRASOUND CORRECTLY ASSESS THE LUMINAL DIMENSIONS OF CORONARY-ARTERY LESIONS - A COMPARISON WITH QUANTITATIVE ANGIOGRAPHY [J].
HAASE, J ;
OZAKI, Y ;
DIMARIO, C ;
ESCANED, J ;
DEFEYTER, PJ ;
ROELANDT, JRTC ;
SERRUYS, PW .
EUROPEAN HEART JOURNAL, 1995, 16 (01) :112-119
[5]   EFFECTS OF LIPID-LOWERING BY PRAVASTATIN ON PROGRESSION AND REGRESSION OF CORONARY-ARTERY DISEASE IN SYMPTOMATIC MEN WITH NORMAL TO MODERATELY ELEVATED SERUM-CHOLESTEROL LEVELS - THE REGRESSION GROWTH EVALUATION STATIN STUDY (REGRESS) [J].
JUKEMA, JW ;
BRUSCHKE, AVG ;
VANBOVEN, AJ ;
REIBER, JHC ;
BAL, ET ;
ZWINDERMAN, AH ;
JANSEN, H ;
BOERMA, GJM ;
VANRAPPARD, FM ;
LIE, KI .
CIRCULATION, 1995, 91 (10) :2528-2540
[6]  
Kimura T, 1997, CIRCULATION, V96, P475
[7]   SEQUENTIAL INTRAVASCULAR ULTRASOUND CHARACTERIZATION OF THE MECHANISMS OF ROTATIONAL ATHERECTOMY AND ADJUNCT BALLOON ANGIOPLASTY [J].
KOVACH, JA ;
MINTZ, GS ;
PICHARD, AD ;
KENT, KM ;
POPMA, JJ ;
SATLER, LF ;
LEON, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1024-1032
[8]   STUDY ON THE NUCLEAR-REACTIONS OF NB-93, TA-181, AND AU-197 INDUCED BY SECONDARY NEUTRONS IN 40 MEV/NUCLEON AR-40 ION COLLISIONS [J].
LI, WX ;
OHKUBO, Y ;
AMBE, S ;
KOBAYASHI, Y ;
IWAMOTO, M ;
MAEDA, H ;
AMBE, F .
CHEMISTRY LETTERS, 1994, (02) :277-280
[9]   HOW DOES ANGIOPLASTY WORK - SERIAL ANALYSIS OF HUMAN ILIAC ARTERIES USING INTRAVASCULAR ULTRASOUND [J].
LOSORDO, DW ;
ROSENFIELD, K ;
PIECZEK, A ;
BAKER, K ;
HARDING, M ;
ISNER, JM .
CIRCULATION, 1992, 86 (06) :1845-1858
[10]   CORONARY-ARTERY LUMEN VOLUME MEASUREMENT USING 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND - VALIDATION OF A NEW TECHNIQUE [J].
MATAR, FA ;
MINTZ, GS ;
DOUEK, P ;
FARB, A ;
VIRMANI, R ;
JAVIER, SP ;
POPMA, JJ ;
PICHARD, AD ;
KENT, KM ;
SATLER, LF ;
KELLER, M ;
LEON, MB .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (03) :214-220