Semi-three-dimensional algorithm for time-resolved diffuse optical tomography by use of the generalized pulse spectrum technique

被引:45
作者
Gao, F [1 ]
Tanikawa, Y [1 ]
Zhao, HJ [1 ]
Yamada, Y [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Inst Human Sci & Biomed Engn, Tsukuba, Ibaraki 3058564, Japan
关键词
D O I
10.1364/AO.41.007346
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Although a full three-dimensional (3-D) reconstruction with both 3-D forward and inverse models provides the optimal solution for diffuse optical tomography (DOT), because of the 3-D nature of photon diffusion in tissue, it is computationally costly for both memory requirement and execution time in a conventional computing environment. Thus in practice there is motivation to develop an image reconstruction algorithm with dimensional reduction based on some modeling approximations. Here we have implemented a semi-3-D modified generalized pulse spectrum technique for time-resolved DOT, where a two-dimensional (2-D) distribution of optical properties is approximately assumed, while we retain 3-D distribution of photon migration in tissue. We have validated the proposed algorithm by reconstructing 3-D structural test objects from both numerically simulated and experimental data. We demonstrate our algorithm by comparing it with the calibrated 2-D reconstruction that is in widespread use as a shortcut to 3-D imaging and proving that the semi-3-D algorithm outperforms the calibrated 2-D algorithm. (C) 2002 Optical Society of America.
引用
收藏
页码:7346 / 7358
页数:13
相关论文
共 30 条
[1]   PHOTON-MEASUREMENT DENSITY-FUNCTIONS .1. ANALYTICAL FORMS [J].
ARRIDGE, SR .
APPLIED OPTICS, 1995, 34 (31) :7395-7409
[2]   PHOTON-MEASUREMENT DENSITY-FUNCTIONS .2. FINITE-ELEMENT-METHOD CALCULATIONS [J].
ARRIDGE, SR ;
SCHWEIGER, M .
APPLIED OPTICS, 1995, 34 (34) :8026-8037
[3]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[4]  
BEVILACQUA F, 1993, APPL OPTICS, V32, P574
[5]   Three-dimensional optical tomography of hemodynamics in the human head [J].
Bluestone, AY ;
Abdoulaev, G ;
Schmitz, CH ;
Barbour, RL ;
Hielscher, AH .
OPTICS EXPRESS, 2001, 9 (06) :272-286
[6]   The accuracy of near infrared spectroscopy and imaging during focal changes in cerebral hemodynamics [J].
Boas, DA ;
Gaudette, T ;
Strangman, G ;
Cheng, XF ;
Marota, JJA ;
Mandeville, JB .
NEUROIMAGE, 2001, 13 (01) :76-90
[7]   GENERALIZED PULSE-SPECTRUM TECHNIQUE [J].
CHEN, YM .
GEOPHYSICS, 1985, 50 (11) :1664-1675
[8]   Tomographic image reconstruction from optical projections in light-diffusing media [J].
Colak, SB ;
Papaioannou, DG ;
tHooft, GW ;
vanderMark, MB ;
Schomberg, H ;
Paasschens, JCJ ;
Melissen, JBM ;
vanAsten, NAAJ .
APPLIED OPTICS, 1997, 36 (01) :180-213
[9]   A COMPARISON OF 2 METHODS FOR SOLVING THE INVERSE SCATTERING PROBLEM FOR ACOUSTIC-WAVES IN AN INHOMOGENEOUS-MEDIUM [J].
COLTON, D ;
MONK, P .
JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 1992, 42 (01) :5-16
[10]   Compact tissue oximeter based on dual-wavelength multichannel time-resolved reflectance [J].
Cubeddu, R ;
Pifferi, A ;
Taroni, P ;
Torricelli, A ;
Valentini, G .
APPLIED OPTICS, 1999, 38 (16) :3670-3680