Poly(lactic-co-glycolic acid) hollow fibre membranes for use as a tissue engineering scaffold

被引:88
作者
Ellis, Marianne J. [1 ]
Chaudhuri, Julian B. [1 ]
机构
[1] Univ Bath, Dept Chem Engn, Ctr Regenerat Med, Bath BA2 7AY, Avon, England
关键词
hollow fibre membrane; PLGA; bone tissue engineering; mass transfer; scaffold; bioreactor;
D O I
10.1002/bit.21093
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 [微生物学]; 0836 [生物工程]; 090102 [作物遗传育种]; 100705 [微生物与生化药学];
摘要
Mass transfer limitations of scaffolds are currently hindering the development of 3-dimensional, clinically viable, tissue engineered constructs. We have developed a poly(lactide-co-glycolide) (PLGA) hollow fibre membrane scaffold that will provide support for cell culture, allow pseudovascularisation in vitro and provide channels for angiogenesis in vivo. We produced P(DL)LGA flat sheet membranes using 1,4-dioxane and 1-methyl-2-pyrrolidinone (NMP) as solvents and water as the nonsolvent, and hollow fibre membranes, using NMP and water, by dry/wet- and wet-spinning. The resulting fibres had an outer diameter of 700 mu m and an inner diameter of 250 mu m with 0.2-1.0 mu m pores on the culture surface. It was shown that varying the air gap and temperature when spinning changed the morphology of the fibres. The introduction of a 50 mm air gap caused a dense skin of 5 mu m thick to form, compared to a skin of 0.5 mu m thick without an air gap. Spinning at 40 degrees C produced fibres with a more open central section in the wall that contained more, larger macrovoids compared to fibres spun at 20 degrees C. Culture of the immortalised osteogenic cell line 560pZIPv.neo (pZIP) was carried out on the P(DL)LGA flat sheets in static culture and in a P(DL)LGA hollow fibre bioreactor under counter-current flow conditions. Attachment and proliferation was statistically similar to tissue culture polystyrene on the flat sheets and was also successful in the hollow fibre bioreactor. The P(DL)LGA hollow fibres are a promising scaffold to address the size limitations currently seen in tissue engineered constructs.
引用
收藏
页码:177 / 187
页数:11
相关论文
共 40 条
[1]
[Anonymous], 1992, ANGEW CHEM-GER EDIT, DOI DOI 10.1002/ANGE.19971091244
[2]
Fluid mechanics, cell distribution, and environment in CellCube bioreacors [J].
Aunins, JG ;
Bader, B ;
Caola, A ;
Griffiths, J ;
Katz, M ;
Licari, P ;
Ram, K ;
Ranucci, CS ;
Zhou, WC .
BIOTECHNOLOGY PROGRESS, 2003, 19 (01) :2-8
[3]
Design of a flow perfusion bioreactor system for bone tissue-engineering applications [J].
Bancroft, GN ;
Sikavitsas, VI ;
Mikos, AG .
TISSUE ENGINEERING, 2003, 9 (03) :549-554
[4]
BERESFORD J, 2002, COMMUNICATION
[5]
BERESFORD JN, 1998, MARROW STROMAL CELL
[6]
Chung TS, 1997, J APPL POLYM SCI, V66, P1067
[7]
EENINK M J D, 1987, Journal of Controlled Release, V6, P225, DOI 10.1016/0168-3659(87)90079-4
[8]
Extracellular matrix production by human osteoblasts cultured on biodegradable polymers applicable for tissue engineering [J].
El-Amin, SF ;
Lu, HH ;
Khan, Y ;
Burems, J ;
Mitchell, J ;
Tuan, RS ;
Laurencin, CT .
BIOMATERIALS, 2003, 24 (07) :1213-1221
[9]
Development of a three-dimensional transmigration assay for testing cell-polymer interactions for tissue engineering applications [J].
Gosiewska, A ;
Rezania, A ;
Dhanaraj, S ;
Vyakarnam, M ;
Zhou, J ;
Burtis, D ;
Brown, L ;
Kong, W ;
Zimmerman, M ;
Geesin, JC .
TISSUE ENGINEERING, 2001, 7 (03) :267-277
[10]
Rotating-wall vessels, promising bioreactors for osteoblastic cell culture: comparison with other 3D conditions [J].
Granet, C ;
Laroche, N ;
Vico, L ;
Alexandre, C ;
Lafage-Proust, MH .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (04) :513-519