Three-dimensional ultrasound angiography (power mode) for the quantification of carotid artery atherosclerosis

被引:34
作者
Griewing, B [1 ]
Walker, ML [1 ]
Schminke, U [1 ]
Kessler, C [1 ]
Morgenstern, C [1 ]
机构
[1] UNIV GREIFSWALD,DEPT NEUROL,D-17487 GREIFSWALD,GERMANY
关键词
D O I
10.1111/jon19977140
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Three-dimensional (3D) ultrasound angiography was performed to diagnose carotid artery atherosclerosis. Thirty-five patients (15 women, 20 men) with a history of cerebrovascular disease were examined using conventional color-coded Doppler ultrasound and 3D ultrasound angiography. Carotid stenosis was initially diagnosed using continuous-wave Doppler ultrasound. To determine intraobserver and interobserver reliabilities, 21 patients were evaluated using 3D ultrasound on three occasions. Sixty-five percent of patients were diagnosed with stenosis of more than 50%. Twenty-two percent of plaques had a smooth surface, 72.9% were ulcerated, and 5.1% were indeterminate. Data collection for 3D imaging required 5 minutes per patient, whereas image processing and plaque volume quantification required 30 minutes. Plaque volume ranged from 0.053 to 0.685 ml. The intraobserver and inter observer variabilities were 4.16 and 5.87%, respectively (r = 0.96, p < 0.0001; r = 0.89, p < 0.0001). 3D Color Doppler and 3D ultrasound angiography assessments of plaque volume differed by 8.5%. Plaques were more precisely differentiated using 3D ultrasound, and plaque volume quantification was less affected by echo shadowing after 3D reconstruction. In comparison to other techniques for the quantification of atherosclerotic lesions, 3D ultrasound angiography offers a more precise quantitative method for prospective, clinical studies of atherosclerosis.
引用
收藏
页码:40 / 45
页数:6
相关论文
共 21 条
[1]   CAROTID ENDARTERECTOMY AND THE MEASUREMENT OF STENOSIS [J].
BARNETT, HJM ;
WARLOW, CP .
STROKE, 1993, 24 (09) :1281-1284
[2]  
BLUTH EI, 1988, RADIOGRAPHICS, V8, P504
[3]  
Delcker A, 1994, EUR J ULTRASOUND, V1, P337
[4]   DIFFERENTIATING SUBTOTAL CAROTID-ARTERY STENOSES FROM OCCLUSIONS BY COLOR-CODED DUPLEX SONOGRAPHY [J].
GORTLER, M ;
NIETHAMMER, R ;
WIDDER, B .
JOURNAL OF NEUROLOGY, 1994, 241 (05) :301-305
[5]  
Griewing B, 1996, Bildgebung, V63, P35
[6]   Cerebrovascular disease assessed by color-flow and power Doppler ultrasonography - Comparison with digital subtraction angiography in internal carotid artery stenosis [J].
Griewing, B ;
Morgenstern, C ;
Driesner, F ;
Kallwellis, G ;
Walker, ML ;
Kessler, C .
STROKE, 1996, 27 (01) :95-100
[7]  
GRIEWING G, 1996, J NEUROIMAGING, V6, P32
[8]   RELATIONS OF INTIMAL-MEDIAL THICKNESS AMONG SITES WITHIN THE CAROTID-ARTERY AS EVALUATED BY B-MODE ULTRASOUND [J].
HOWARD, G ;
BURKE, GL ;
EVANS, GW ;
CROUSE, JR ;
RILEY, W ;
ARNETT, D ;
DELACY, R ;
HEISS, G .
STROKE, 1994, 25 (08) :1581-1587
[9]   CAROTID-ARTERY INTIMAL-MEDIAL THICKNESS DISTRIBUTION IN GENERAL POPULATIONS AS EVALUATED BY B-MODE ULTRASOUND [J].
HOWARD, G ;
SHARRETT, AR ;
HEISS, G ;
EVANS, GW ;
CHAMBLESS, LE ;
RILEY, WA ;
BURKE, GL .
STROKE, 1993, 24 (09) :1297-1304
[10]  
JAHN SP, 1991, ULTRASOUND MED BIOL, V17, P49