Deformations of the isolated mouse tectorial membrane produced by oscillatory forces

被引:50
作者
Abnet, CC
Freeman, DM
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[3] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[4] Massachusetts Eye & Ear Infirm, Eaton Peabody Lab Auditory Physiol, Boston, MA 02114 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
cochlea; tectorial membrane; magnetic bead; viscoelastic; mechanical coupling; anisotropy; micromechanics; mouse;
D O I
10.1016/S0378-5955(00)00041-1
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Mechanical properties of the isolated tectorial membrane (TM) of the mouse were measured by applying oscillatory shear forces to the TM with a magnetic bead (radius similar to 10 um). Sinusoidal forces at 10 Hz with amplitudes from 5 to 33 nN were applied tangentially to the surfaces of 11 TMs. The ratio of force to bead displacement ranged from 0.04 to 0.98 N/m (median: 0.18 N/m, interquartile range: 0.11-0.30 N/m, n = 90). Increasing frequency from 10 to 100 Hz decreased the magnitude of the displacement of the magnetic bead by 6-7.3 dB/decade. The phase of the displacement lagged that of the stimulus current by approximately 27-44 degrees across frequencies. Displacement of the adjacent tissue decreased as the distance from the magnetic bead increased. Space constants were of the order of tens of micrometers. Forces with equal amplitude and frequency were applied radially and longitudinally. Longitudinal displacements in response to longitudinal forces were 1-10 times as large as radial displacements in response to radial forces in 85% of 560 paired measurements. These results suggest that the following mechanical properties of the TM are important. (1) Viscoelasticity: The frequency dependence of TM displacement lies between that of a purely viscous and a purely elastic material, suggesting that both are important. (2) Mechanical coupling: Space constants indicate that hair bundles could interact mechanically with adjacent hair bundles via the TM. (3) Anisotropy: The mechanical impedance is greater in the radial direction than it is in the longitudinal direction. This mechanical anisotropy correlates with anatomical anisotropies, such as the radially oriented fibrillar structure of the TM. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:29 / 46
页数:18
相关论文
共 62 条
[1]  
ABNET CC, 1998, 21 MIDW RES M ST PET, P183
[2]  
ABNET CC, 1997, 20 MIDW RES M ST PET, P13
[3]   COCHLEAR MICROMECHANICS - A PHYSICAL MODEL OF TRANSDUCTION [J].
ALLEN, JB .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 68 (06) :1660-1670
[4]  
[Anonymous], 1956, MECH VIBRATIONS
[5]   Local measurements of viscoelastic parameters of adherent cell surfaces by magnetic bead microrheometry [J].
Bausch, AR ;
Ziemann, F ;
Boulbitch, AA ;
Jacobson, K ;
Sackmann, E .
BIOPHYSICAL JOURNAL, 1998, 75 (04) :2038-2049
[6]   TRANSMISSION OF RADIAL SHEAR FORCES TO COCHLEAR HAIR CELLS [J].
BILLONE, M ;
RAYNOR, S .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1973, 54 (05) :1143-1156
[7]   NONLINEAR MECHANICS AT THE APEX OF THE GUINEA-PIG COCHLEA [J].
COOPER, NP ;
RHODE, WS .
HEARING RESEARCH, 1995, 82 (02) :225-243
[8]  
DALLOS P, 1972, SCIENCE, V177, P356, DOI 10.1126/science.177.4046.356
[9]   Statistics of subpixel registration algorithms based on spatiotemporal gradients or block matching [J].
Davis, CQ ;
Freeman, DM .
OPTICAL ENGINEERING, 1998, 37 (04) :1290-1298
[10]   Using a light microscope to measure motions with nanometer accuracy [J].
Davis, CQ ;
Freeman, DM .
OPTICAL ENGINEERING, 1998, 37 (04) :1299-1304