Single beam two-views holographic particle image velocimetry

被引:94
作者
Sheng, J [1 ]
Malkiel, E [1 ]
Katz, J [1 ]
机构
[1] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD 21218 USA
关键词
D O I
10.1364/AO.42.000235
中图分类号
O43 [光学];
学科分类号
070207 [光学]; 0803 [光学工程];
摘要
Holographic particle image velocimetry (HPIV) is presently the only method that can measure at high resolution all three components of the velocity in a finite volume. In systems that are based on recording one hologram, velocity components parallel to the hologram can be measured throughout the sample volume, but elongation of the particle traces in the depth direction severely Emits the accuracy of the velocity component that is perpendicular to the hologram. Previous studies overcame this limitation by simultaneously recording two orthogonal holograms, which inherently required four windows and two recording systems. This paper introduces a technique that maintains the advantages of recording two orthogonal views, but requires only one window and one recording system. Furthermore, it enables a quadruple increase in the spatial resolution. This method is based on placing a mirror in the test section that reflects the object beam at an angle of 45degrees. Particles located in the volume in which the incident and reflected beams from the mirror overlap are illuminated twice in perpendicular directions. Both views are recorded on the same hologram. Off-axis holography with conjugate reconstruction and high-pass filtering is used for recording and analyzing the holograms. Calibration tests show that two views reduce the uncertainty in the three-dimensional (3-D) coordinates of the particle centroids to within a few microns. The velocity is still determined plane-by-plane by use of two-dimensional particle image velocimetry procedures, but the images are filtered to trim the elongated traces based on the 3-D location of the particle. Consequently, the spatial resolution is quadrupled. Sample data containing more than 200 particles/mm(3) are used for calculating the 3-D velocity distributions with interrogation volumes of 220 x 154 x 250 mum, and vector spacing of 110 x 77 x 250 mum. Uncertainty in velocity is addressed by examining how well the data satisfies the continuity equation. The results show significant improvements compared with previous. procedures. Limitations of the technique are also discussed. (C) 2003 Optical Society of America.
引用
收藏
页码:235 / 250
页数:16
相关论文
共 13 条
[1]
PHASE-CONJUGATE HOLOGRAPHIC SYSTEM FOR HIGH-RESOLUTION PARTICLE-IMAGE VELOCIMETRY [J].
BARNHART, DH ;
ADRIAN, RJ ;
PAPEN, GC .
APPLIED OPTICS, 1994, 33 (30) :7159-7170
[2]
COLLIER RJ, 1971, OPTICAL HOLOGRAPHY, P232
[3]
SUPERRESOLUTION PARTICLE IMAGING VELOCIMETRY [J].
KEANE, RD ;
ADRIAN, RJ ;
ZHANG, Y .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (06) :754-768
[4]
Measurements of plankton distribution in the ocean using submersible holography [J].
Malkiel, E ;
Alquaddoomi, O ;
Katz, J .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (12) :1142-1152
[5]
IN-LINE RECORDING AND OFF-AXIS VIEWING TECHNIQUE FOR HOLOGRAPHIC PARTICLE VELOCIMETRY [J].
MENG, H ;
HUSSAIN, F .
APPLIED OPTICS, 1995, 34 (11) :1827-1840
[6]
PRATT WK, 1992, DIGITAL IMAGE PROCES, P59
[7]
An advanced off-axis holographic particle image velocimetry (HPIV) system [J].
Pu, Y ;
Meng, H .
EXPERIMENTS IN FLUIDS, 2000, 29 (02) :184-197
[8]
Measurements of the flow structure and turbulence within a ship bow wave [J].
Roth, GI ;
Mascenik, DT ;
Katz, J .
PHYSICS OF FLUIDS, 1999, 11 (11) :3512-3523
[9]
Five techniques for increasing the speed and accuracy of PIV interrogation [J].
Roth, GI ;
Katz, J .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (03) :238-245
[10]
DRAG AND LIFT FORCES ON MICROSCOPIC BUBBLES ENTRAINED BY A VORTEX [J].
SRIDHAR, G ;
KATZ, J .
PHYSICS OF FLUIDS, 1995, 7 (02) :389-399