Dual-energy CT angiography of pelvic and lower extremity arteries: dual-energy bone subtraction versus manual bone subtraction

被引:25
作者
Yamamoto, S. [1 ]
McWilliams, J. [1 ]
Arellano, C. [1 ]
Marfori, W. [1 ]
Cheng, W. [1 ]
McNamara, T. [1 ]
Quinones-Baldrich, W. J. [1 ]
Ruehm, S. G. [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol, Los Angeles, CA 90095 USA
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DIGITAL-SUBTRACTION; CONVENTIONAL ANGIOGRAPHY; CEREBRAL ANEURYSMS; OCCLUSIVE DISEASE; MR-ANGIOGRAPHY; MULTISLICE-CT; HELICAL CT; FEASIBILITY; ELIMINATION;
D O I
10.1016/j.crad.2009.07.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
AIM: To analyse the effect of dual-energy bone subtraction (DEBS) on the image quality of peripheral computed tomography (CT) angiograms. MATERIALS AND METHODS: Twenty patients underwent dual-energy CT angiography of the pelvic and lower extremity arteries using commercially available equipment. Two different methods of image processing were employed for each CT angiographic dataset: (1) DEBS, and (2) manual bone subtraction (MBS). Effects on vessel visibility and artificial vessel alterations were compared. RESULTS: Bone removal, and the resultant visibility of vessel segments, were significantly better with DEBS than with MBS (p = 0.011). The overall frequency of vessel-related alterations was lower in MBS compared with DEBS (p = 0.001). Specifically, in the 249 vessel segments with calcified plaques, MBS generated fewer vessel alterations than DEBS (p < 0.001). In the 309 vessel segments without calcified plaques, there was no difference in vessel alteration between the two techniques (p = 0.22). CONCLUSION: DEBS facilitates bone removal in peripheral CT angiography, but generates more vessel alterations, particularly in the presence of calcified plaque. (C) 2009 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1088 / 1096
页数:9
相关论文
共 22 条
[1]
16-MDCT angiography of aortoiliac and lower extremity arteries: Comparison with digital subtraction angiography [J].
Albrecht, Thomas ;
Foert, Ellen ;
Holtkamp, Robin ;
Kirchin, Miles A. ;
Ribbe, Constanze ;
Wacker, Frank K. ;
Kruschewski, Martin ;
Meyer, Bernhard C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) :702-711
[2]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[3]
Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography [J].
Dammert, S ;
Krings, T ;
Moller-Hartmann, W ;
Ueffing, E ;
Hans, FJ ;
Willmes, K ;
Mull, M ;
Thron, A .
NEURORADIOLOGY, 2004, 46 (06) :427-434
[4]
First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[5]
GORZER H, 1994, J COMPUT ASSIST TOMO, V18, P839, DOI 10.1097/00004728-199409000-00031
[6]
Heuschmid M, 2003, EUR J MED RES, V8, P389
[7]
Multi-slice 3D-CTA - An improvement over single slice helical CTA for cerebral aneurysms [J].
Kato, Y ;
Nair, S ;
Sano, H ;
Sanjaykumar, MS ;
Katada, K ;
Hayakawa, M ;
Kanno, T .
ACTA NEUROCHIRURGICA, 2002, 144 (07) :715-722
[8]
Multi-detector row computed tomography angiography of peripheral arterial disease [J].
Kock, Marc C. J. M. ;
Dijkshoorn, Marcel L. ;
Pattynama, Peter M. T. ;
Hunink, M. G. Myriam .
EUROPEAN RADIOLOGY, 2007, 17 (12) :3208-3222
[9]
DSA versus multi-detector row CT angiography in peripheral arterial disease: Randomized controlled trial [J].
Kock, MCJM ;
Adriaensen, MEAPM ;
Pattynama, PMT ;
van Sambeek, MRHM ;
van Urk, H ;
Stijnen, T ;
Hunink, MGM .
RADIOLOGY, 2005, 237 (02) :727-737
[10]
Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging [J].
Lell, M ;
Anders, K ;
Klotz, E ;
Ditt, H ;
Bautz, W ;
Tomandl, BF .
EUROPEAN RADIOLOGY, 2006, 16 (04) :889-897