Coreless printed circuit board (PCB) transformers with high power density and high efficiency

被引:8
作者
Tang, SC [1 ]
Hui, SYR [1 ]
Chung, H [1 ]
机构
[1] City Univ Hong Kong, Dept Elect Engn, Kowloon, Hong Kong, Peoples R China
关键词
D O I
10.1049/el:20000694
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The authors report the use of a coreless printed circuit board transformer for power conversion with very high power density and efficiency. A coreless PCB transformer with an outermost radius of similar to 1 cm and 19 turns for both the primary and secondary windings can transfer 19W at an efficiency of 90%, resulting in a record power density of 24 W/cm2. The power density and energy efficiency of a coreless PCB transformer are higher than those of core-based microtransformers. Coreless transformers are simpler in structure, easier to implement in silicon wafer and cheaper than core-based planar transformers.