Physicochemical Characterization of Biomaterials Commonly Used in Dentistry as Bone Substitutes-Comparison with Human Bone

被引:118
作者
Figueiredo, Margarida [1 ]
Henriques, Jose [2 ]
Martins, Gabriela [1 ]
Guerra, Fernando [2 ]
Judas, Fernando [3 ]
Figueiredo, Helena [4 ]
机构
[1] Univ Coimbra, Dept Chem Engn, P-3030290 Coimbra, Portugal
[2] Univ Coimbra, Dept Dent, P-3030005 Coimbra, Portugal
[3] Hosp Univ Coimbra, Coimbra Univ Hosp, Dept Orthopaed, P-3000075 Coimbra, Portugal
[4] Univ Coimbra, Histol Inst, P-3004504 Coimbra, Portugal
关键词
bone graft; FTIR; hydroxy(1)apatite; morphology; porosity; X-RAY-DIFFRACTION; SINUS AUGMENTATION; GRAFT SUBSTITUTES; DENTAL IMPLANTS; HYDROXYAPATITE; PEPTIDE; SCAFFOLDS; CARBONATE; DEFECTS; CORAL;
D O I
10.1002/jbm.b.31529
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The present work focuses on the physicochemical characterization of selected mineral-based biomaterials that are frequently used in dental applications. The selected materials are commercially available as granules from different biological origins: bovine, porcine, and coralline. Natural and calcined human bone were used for comparison purposes. Besides a classical rationalization of chemical composition and crystallinity, a major emphasis was placed on the measurement of various morphostructural properties such as particle size, porosity, density, and specific surface area. Such properties are crucial to acquiring a full interpretation of the in vivo performance. The studied samples exhibited distinct particle sizes (between 200 and 1000 mu m) and shapes. Mercury intrusion revealed not only that the total sample porosity varied considerably (33% for OsteoBiol (R), 50% for PepGen P-15 (R), and 60% for BioOss (R)) but also that a significant percentage of that porosity corresponded to submicron pores. Biocoral (R) was not analyzed by this technique as it possesses larger pores than those of the porosimeter upper limit. The density values determined for the calcined samples were close to the theoretical values of hydroxyapatite. However, the values for the collagenated samples were lower, in accordance with their lower mineral content. The specific surface areas ranged from less than 1 m(2)/g (Biocoral) up to 60 m(2)/g (BioOss). The chemical and phase composition of most of the samples, the exception being Biocoral (aragonite), were hydroxyapatite based. Nonetheless, the samples exhibited different organic material content as a consequence of the distinct heat treatments that each had received. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 92B: 409-419, 2010
引用
收藏
页码:409 / 419
页数:11
相关论文
共 61 条
[1]
Allen T., 1999, PARTICLE SIZE MEASUR, V1
[2]
Allen T., 1999, Particle Size Measurement - Surface area and pore size determination, VII
[3]
An ultrastructural study of cellular response to variation in porosity in phase-pure hydroxyapatite [J].
Annaz, B ;
Hing, KA ;
Kayser, M ;
Buckland, T ;
Di Silvio, L .
JOURNAL OF MICROSCOPY-OXFORD, 2004, 216 (02) :97-109
[4]
Calculating shape factors from particle sizing data [J].
Barreiros, FM ;
Ferreira, PJ ;
Figueiredo, MM .
PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 1996, 13 (06) :368-373
[5]
Natural bioceramics: from coral to bone and beyond [J].
Ben-Nissan, B .
CURRENT OPINION IN SOLID STATE & MATERIALS SCIENCE, 2003, 7 (4-5) :283-288
[6]
Betz RR, 2002, ORTHOPEDICS, V25, pS561
[7]
*BIOC INC, 2008, PROD INF BIOC
[8]
Sinus augmentation for dental implants: The use of autogenous bone [J].
Block, MS ;
Kent, JN .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1997, 55 (11) :1281-1286
[9]
Carvalho Alexandre L, 2007, J Oral Implantol, V33, P267, DOI 10.1563/1548-1336(2007)33[267:EOGSOT]2.0.CO
[10]
2