Direct digital mammography image acquisition

被引:31
作者
Cowen, AR [1 ]
Parkin, GJS [1 ]
Hawkridge, P [1 ]
机构
[1] GEN INFIRM, DEPT DIAGNOST RADIOL, LEEDS LS1 3EX, W YORKSHIRE, ENGLAND
基金
英国惠康基金;
关键词
X-ray image acquisition; screen-film mammography; computed radiography; computed mammography; CR image plate; direct digital mammography; signal-to-noise ratio; detective quantum efficiency; charge coupled device; hydrogenated amorphous silicon; thin film transistors; amorphous selenium;
D O I
10.1007/s003300050228
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Mammography is a branch of radiology which could benefit greatly from the assimilation of digital imaging technologies. Computerized enhancement techniques could be used to ensure optimum presentation of all clinical images. Beyond this it will facilitate powerful new clinical resources such as computer-assisted diagnosis, tele-mammography, plus digital image management and archiving. An essential precursor to all these advances is the availability of appropriate direct digital mammography (DDM) image-acquisition system(s) to capture high-quality breast X-ray image data at the outset. The only practical DDM image-acquisition system currently available is (photo-stimulable phosphor) computed radiography. Modern computed mammography (CM) uses similar radiation doses to the patient and produces equivalent, albeit different, image quality to screen-film mammography. Computed mammography offers superior rendition of the skin edge and sub-cutaneous tissue and dense parenchyma, while ensuring equivalent micro-calcification detectability. Meanwhile, a variety of new technical approaches to DDM are under active investigation and/or development which promise to supercede film-based mammography. These new (second generation) DDM technologies promise the radiologist superior image quality combined with significant dose savings compared with contemporary imaging systems. In this review we describe and compare the physical and clinical characteristics of CM and the various emerging DDM image-acquisition technologies.
引用
收藏
页码:918 / 930
页数:13
相关论文
共 59 条
[1]   THIN-FILM, FLAT-PANEL, COMPOSITE IMAGERS FOR PROJECTION AND TOMOGRAPHIC IMAGING [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
LAM, KL ;
MORTON, EJ ;
TENHAKEN, RK ;
YORKSTON, J ;
CLINTHORNE, NH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (03) :482-490
[2]   A CLINICAL COMPARISON BETWEEN CONVENTIONAL AND DIGITAL MAMMOGRAPHY UTILIZING COMPUTED RADIOGRAPHY [J].
BRETTLE, DS ;
WARD, SC ;
PARKIN, GJS ;
COWEN, AR ;
SUMSION, HJ .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797) :464-468
[3]  
BRETTLE DS, 1994, INT CONGR SER, V1069, P163
[4]  
CHEUNG L, 1995, MED ELECT, V26, P50
[5]  
CHINNOCK C, 1995, DIAGN IMAGING, V17, P133
[6]   A PRELIMINARY INVESTIGATION OF THE IMAGING PERFORMANCE OF PHOTOSTIMULABLE PHOSPHOR COMPUTED RADIOGRAPHY USING A NEW DESIGN OF MAMMOGRAPHIC QUALITY-CONTROL TEST OBJECT [J].
COWEN, AR ;
BRETTLE, DS ;
COLEMAN, NJ ;
PARKIN, GJS .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (774) :528-535
[7]  
COWEN AR, 1995, IMAGING, V7, P204
[8]  
COWEN AR, 1994, IMAGING, V6, P77
[9]  
DANCE DR, 1988, PHYSICS MED IMAGING, P20
[10]   USE OF DIGITAL MAMMOGRAPHY IN NEEDLE LOCALIZATION PROCEDURES [J].
DERSHAW, DD ;
FLEISCHMAN, RC ;
LIBERMAN, L ;
DEUTCH, B ;
ABRAMSON, AF ;
HANN, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (03) :559-562