Effects of different implant surfaces and designs on marginal bone-level alterations: a review

被引:95
作者
Abrahamsson, Ingemar [1 ]
Berglundh, Tord [1 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Dept Periodontol, S-40530 Gothenburg, Sweden
关键词
ankylos; bone level; bone loss; dental implants; implant design; implant geometry; implant surface; machined; micro-thread; OsseoSpeed; Osseotite; platform-switch; SLA; TiOblast; TiUnite and turned; FIXED PARTIAL DENTURES; BRANEMARK SYSTEM IMPLANTS; DENTAL IMPLANTS; FOLLOW-UP; ASTRA TECH; RADIOGRAPHIC EVALUATION; PROSPECTIVE MULTICENTER; CLINICAL-EVALUATION; ITI IMPLANTS; 3I IMPLANTS;
D O I
10.1111/j.1600-0501.2009.01783.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective The purpose of this review was to evaluate the effect of different implant surfaces and designs on marginal bone-level (MBL) alterations. Material and methods A MEDLINE search (PubMed) was performed to identify clinical, prospective and controlled studies using a sufficient sample size (> 10 subjects) and with a follow-up time of >= 3 years. Results Ten publications fulfilled the inclusion criteria. Two studies evaluated the influence of implant surface characteristics and two studies reported on the effect of implant design on MBL changes. Six publications analyzed the combined effect of different implant surfaces and designs on MBL alterations. As revealed from available studies, there is no evidence that modified surfaces are superior to non-modified implant surfaces in marginal bone preservation. One study reported on significantly improved MBL preservation for implants with a conical and micro-threaded marginal collar than implants with a cylindrical and non-threaded marginal portion after 3 years in function. No implant system was found to be superior in marginal bone preservation. To cite this article:Abrahamsson I, Berglundh T. Effects of different implant surfaces and designs on marginal bone-level alterations: a systematic review.Clin. Oral Impl. Res. 20 (Suppl. 4), 2009; 207-215.doi: 10.11117/j.1600-0501.2009.01783.x.
引用
收藏
页码:207 / 215
页数:9
相关论文
共 42 条
[1]  
Aalam AA, 2005, INT J ORAL MAX IMPL, V20, P793
[2]   Tissue characteristics at microthreaded implants: An experimental study in dogs [J].
Abrahamsson, Ingemar ;
Berglundh, Tord .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2006, 8 (03) :107-113
[3]   Turned, machined versus double-etched dental implants in vivo [J].
Al-Nawas, B. ;
Hangen, U. ;
Duschner, H. ;
Krummenauer, F. ;
Wagner, W. .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2007, 9 (02) :71-78
[4]  
Arlin ML, 2007, J CAN DENT ASSOC, V73, P821
[5]   Astra Tech and Branemark system implants:: a 5-year prospective study of marginal bone reactions [J].
Åstrand, P ;
Engquist, B ;
Dahlgren, S ;
Gröndahl, K ;
Engquist, E ;
Feldmann, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :413-420
[6]  
Astrand Per, 2004, Clin Implant Dent Relat Res, V6, P130, DOI 10.1111/j.1708-8208.2004.tb00213.x
[7]   Mandibular overdentures supported by two Branemark, IMZ or ITI implants - A prospective comparative preliminary study: One-year results [J].
Batenburg, RHK ;
Meijer, HJA ;
Raghoebar, GM ;
Van Oort, RP ;
Boering, G .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (06) :374-383
[8]  
Becker W, 2000, Clin Implant Dent Relat Res, V2, P159, DOI 10.1111/j.1708-8208.2000.tb00007.x
[9]   A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years [J].
Berglundh, T ;
Persson, L ;
Klinge, B .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2002, 29 :197-212
[10]   Bone reactions to longstanding functional load at implants: an experimental study in dogs [J].
Berglundh, T ;
Abrahamsson, I ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (09) :925-932