Surface treatment of flexor tendon autografts with carbodiimide-derivatized hyaluronic acid - An in vivo canine model

被引:64
作者
Zhao, Chunfeng [1 ]
Sun, Yu-Long [1 ]
Amadio, Peter C. [1 ]
Tanaka, Toshikazu [1 ]
Ettema, Anke M. [1 ]
An, Kai-Nan [1 ]
机构
[1] Mayo Clin, Coll Med, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
关键词
D O I
10.2106/JBJS.E.00871
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Clinical and experimental studies have demonstrated that restrictive adhesions and poor digital motion are common complications after extrasynovial tendon grafting in an intrasynovial environment. The purpose of this study was to test the hypothesis that surface modification of an extrasynovial tendon with use of a carbodiimide-derivatized hyaluronic acid-gelatin polymer (cd-HA) improves gliding ability and digital function after tendon grafting in a canine model in vivo. Methods: The peroneus longus tendons from both hindpaws of twenty-four dogs were harvested and transplanted to replace the flexor digitorum profundus tendons in the second and fifth digits of one forepaw. Prior to grafting, one of the peroneus longus tendons was coated with cd-HA, which consists of 1% hyaluronic acid, 10% gelatin, 0.25% 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC), and 0.25% N-hydroxysuccinimide (NHS), while the other was immersed in saline solution only. Eight dogs were killed at one, three, and six weeks. Digital normalized work of flexion, tendon gliding resistance, and hyaluronic acid quantification (with the hyaluronic acid-binding-protein staining technique) were the outcome measures. Results: The normalized work of flexion of the tendons treated with cd-HA was significantly lower than that of the saline-solution-treated controls at each time-point (p < 0.05). The gliding resistance of the cd-HA group was significantly lower than that of the saline-solution group at three and six weeks (p < 0.05). The ratio between the intensity of staining of the cd-HA-treated tendons with that of the saline-solution-treated controls was significantly greater at time-0 than at three or six weeks (p < 0.05), but there was no significant difference between time-0 and one-week values. Conclusions: Treating the surface of an extrasynovial tendon autograft with a carbodiimide-derivatized hyaluronic acid-gelatin polymer decreases digital work of flexion and tendon gliding resistance in this flexor tendon graft model in vivo. Clinical Relevance: cd-HA gelatin may provide surgeons with a new and useful method to improve the quality of tendon graft surgery.
引用
收藏
页码:2181 / 2191
页数:11
相关论文
共 69 条
[1]
AUTOGENOUS FLEXOR TENDON GRAFTS - FIBROBLAST ACTIVITY AND MATRIX REMODELING IN DOGS [J].
ABRAHAMSSON, SO ;
GELBERMAN, RH ;
AMIEL, D ;
WINTERTON, P ;
HARWOOD, F .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (01) :58-66
[2]
ALURENT TC, 1998, CHEM BIOL MED APPL H, P33
[3]
STAGED FLEXOR TENDON RECONSTRUCTION IN THE FINGERS AND HAND [J].
AMADIO, PC ;
WOOD, MB ;
COONEY, WP ;
BOGARD, SD .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (04) :559-562
[4]
AMADIO PC, 1986, ORTHOP T, V10, P212
[5]
HYALURONAN IN FLEXOR TENDON REPAIR [J].
AMIEL, D ;
ISHIZUE, K ;
BILLINGS, E ;
WIIG, M ;
VANDEBERG, J ;
AKESON, WH ;
GELBERMAN, R .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14A (05) :837-843
[6]
An K N, 1993, Biomed Sci Instrum, V29, P1
[7]
LOCALIZATION OF HYALURONIC-ACID IN HUMAN ARTICULAR-CARTILAGE [J].
ASARI, A ;
MIYAUCHI, S ;
KURIYAMA, S ;
MACHIDA, A ;
KOHNO, K ;
UCHIYAMA, Y .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1994, 42 (04) :513-522
[8]
THE DISTRIBUTION OF HYALURONAN IN HUMAN SKIN AND MATURE, HYPERTROPHIC AND KELOID SCARS [J].
BERTHEIM, U ;
HELLSTROM, S .
BRITISH JOURNAL OF PLASTIC SURGERY, 1994, 47 (07) :483-489
[9]
Bulpitt P, 1999, J BIOMED MATER RES, V47, P152
[10]
MORPHOLOGIC AND BIOMECHANICAL COMPARISON OF TENDONS USED AS FREE GRAFTS [J].
CARLSON, GD ;
BOTTE, MJ ;
JOSEPHS, MS ;
NEWTON, PO ;
DAVIS, JLW ;
WOO, SLY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (01) :76-82