Oral anticoagulation self-management and management by a specialist anticoagulation clinic:: a randomised cross-over comparison

被引:227
作者
Cromheecke, ME
Levi, M
Colly, LP
de Mol, BJM
Prins, MH
Hutten, BA
Mak, R
Keyzers, KCJ
Büller, HR
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Cardiopulm Surg, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Vasc Med, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Internal Med, NL-1105 AZ Amsterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1105 AZ Amsterdam, Netherlands
[5] Amsterdam Thrombosis Serv, Amsterdam, Netherlands
关键词
D O I
10.1016/S0140-6736(00)02470-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Vitamin K antagonist treatment is effective for prevention and treatment of thromboembolic events but frequent laboratory control and dose-adjustment are essential. Small portable devices have enabled patient self-monitoring of anticoagulation and self-adjustment of the dose. We compared this self-management of oral anticoagulant therapy with conventional management by a specialist anticoagulation clinic in a randomised cross-over study. Methods 50 patients on long-term oral anticoagulant treatment were included in a randomised controlled crossover study. Patients were self-managed or were managed by the anticoagulation clinic for a period of 3 months. After this period the alternative strategy was followed for each patient. Prothrombin time (expressed as international normalised ratio [INR]) were measured at intervals of 1-2 weeks in both periods without knowledge of type of management. The primary endpoint was the number of measurements within the therapeutic range (therapeutic target value +/-50.5 INR units). Findings There was no significant difference in the overall quality of control of anticoagulation between the two study periods. Patients were for 55% and for 49% of the treatment period within a range of +/-0.5 from the therapeutic target INR during self-management and anticoagulation clinic management, respectively (p=0.06). The proportion of patients who spent most time in the therapeutic target range was larger during self-management than during anticoagulation clinic-guided management. The odds ratio for a better control of anticoagulation (defined as the period of time in the therapeutic target range) during self-management compared with anticoagulation clinic-guided management was 4.6 (95% CI 2.1-10.2). A patient-satisfaction assessment showed superiority of self-management over conventional care. Interpretation Self-management of INR in the population in this study is feasible and appears to result in control of anticoagulation that is at least equivalent to management by a specialist anticoagulation clinic. It is also better appreciated by patients. Larger studies are required to assess the effect of this novel management strategy on the incidence of thromboembolic or bleeding complications.
引用
收藏
页码:97 / 102
页数:6
相关论文
共 35 条
[1]   EVALUATION OF A PORTABLE PROTHROMBIN TIME MONITOR FOR HOME-USE BY PATIENTS WHO REQUIRE LONG-TERM ORAL ANTICOAGULANT-THERAPY [J].
ANDERSON, DR ;
HARRISON, L ;
HIRSH, J .
ARCHIVES OF INTERNAL MEDICINE, 1993, 153 (12) :1441-1447
[2]  
[Anonymous], HDB PSYCHOL DIABETES
[3]   Empowering patients to monitor and manage oral anticoagulation therapy [J].
Ansell, JE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (02) :182-183
[4]   LONG-TERM PATIENT SELF-MANAGEMENT OF ORAL ANTICOAGULATION [J].
ANSELL, JE ;
PATEL, N ;
OSTROVSKY, D ;
NOZZOLILLO, E ;
PETERSON, AM ;
FISH, L .
ARCHIVES OF INTERNAL MEDICINE, 1995, 155 (20) :2185-2189
[5]  
AZAR AJ, 1994, THROMB HAEMOSTASIS, V72, P347
[6]  
BERNARDO A, 1996, J THROMB THROMBOLYS, V2, P321
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   OPTIMAL ORAL ANTICOAGULANT-THERAPY IN PATIENTS WITH MECHANICAL HEART-VALVES [J].
CANNEGIETER, SC ;
ROSENDAAL, FR ;
WINTZEN, AR ;
VANDERMEER, FJM ;
VANDENBROUCKE, JP ;
BRIET, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (01) :11-17
[9]  
CORTELAZZO S, 1993, THROMB HAEMOSTASIS, V69, P316
[10]   Accuracy of a portable international normalization ratio monitor in outpatients receiving long-term oral anticoagulant therapy: Comparison with a laboratory reference standard using clinically relevant criteria for agreement [J].
Douketis, JD ;
Lane, A ;
Milne, J ;
Ginsberg, JS .
THROMBOSIS RESEARCH, 1998, 92 (01) :11-17