Performance of a dose-defining insulin infusion protocol among trauma service intensive care unit admissions

被引:31
作者
Braithwaite, Susan S.
Edkins, Renee
MacGregor, Kathy L.
Sredzienski, Edward S.
Houston, Michael
Zarzaur, Ben
Rich, Preston B.
Benedetto, Bernard
Rutherford, Edmund J.
机构
[1] Univ N Carolina, Chapel Hill, NC USA
[2] Brown Med Sch, Providence, RI USA
[3] Univ N Carolina WakeMed, Raleigh, NC USA
关键词
D O I
10.1089/dia.2006.8.476
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Among critically ill patients, glycemic control reduces mortality and morbidities, but the use of intravenous insulin infusion is complicated by hypoglycemia. Having a standardized algorithm increases the likelihood of effective and safe utilization of intravenous insulin therapy. A tabular dose-defining protocol for intravenous insulin infusion is described, containing design elements intended to minimize risk for hypoglycemia while seeking control in a narrow target range, and performance is evaluated among critically ill trauma service patients. Methods: The protocol assigns insulin infusion rate (IR) for ranges of blood glucose (BG). The columns are arranged in order of increasing maintenance rate (MR) for insulin infusion. Patient column assignment is determined according to rate of change of BG. During stable column assignment, the IR is a function of column MR and BG. Within-column, the protocol formula provides that (a) for BG between 70 mg/dL and target BG, the IR increases exponentially to the column MR; and (b) for BG above upper target BG range, the IR increases linearly as an adaptation of the rule of 1800, with slope determined by the column MR. Values for IR calculated by formula are rounded to correspond to BG ranges of the table. Performance was assessed in 27 sequential runs among 24 trauma service patients admitted to a surgical intensive care unit (2004-2005). Results: Using point-of-care measurements, mean preinfusion BG was 230.0 +/- 67.9 mg/dL. BG <140 mg/dL was reached during all 27 runs (median time 5.0 h), and target BG was <110 mg/dL during 25 runs (median time 11.0 h). For the group of runs attaining target before interruption of insulin infusion, the average +/- SD of the principal measure of glycemic control, the within-run mean BG, was 113.7 +/- 14.8 mg/dL (coefficient of variation 13%, n = 25 runs). After attaining target, the average within-run SD for BG was 22.9 mg/dL. The within-run frequency of hypoglycemic measurements (BG <70 mg/dL) as a percentage of BG determinations was 2.4%. In this series, no instance of BG <50 mg/dL was seen. Conclusions: This report describes a nurse-implemented tabular protocol for intravenous insulin infusion having the advantages of efficacy, safety, and simplicity of use. Wide variability of IR in the neighborhood of BG 110 mg/dL is associated with stable BG response, and protection against hypoglycemia is achieved by rapid decline of IR at BGs in or below the target range.
引用
收藏
页码:476 / 488
页数:13
相关论文
共 46 条
[1]   Intensive insulin therapy in critical illness - When is the evidence enough? [J].
Angus, DC ;
Abraham, E .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 172 (11) :1358-1359
[2]  
Bland DK, 2005, AM J CRIT CARE, V14, P370
[3]  
Bode Bruce W, 2004, Endocr Pract, V10 Suppl 2, P71
[4]  
BOLDERMAN KM, 2002, PUTTING YOUR PATIENT, P19
[5]  
Braithwaite Susan S, 2006, Endocr Pract, V12 Suppl 3, P72
[6]   Intravenous insulin nomogram improves blood glucose control in the critically ill [J].
Brown, G ;
Dodek, P .
CRITICAL CARE MEDICINE, 2001, 29 (09) :1714-1719
[7]   Management of diabetes and is hyperglycemia in hospitals [J].
Clement, S ;
Braithwaite, SS ;
Magee, MF ;
Ahmann, A ;
Smith, EP ;
Schafer, RG ;
Hirsh, IB .
DIABETES CARE, 2004, 27 (02) :553-591
[8]   Glucommander - A computer-directed intravenous insulin system shown to be safe, simple, and effective in 120,618 h of operation [J].
Davidson, PC ;
Steed, RD ;
Bode, BW .
DIABETES CARE, 2005, 28 (10) :2418-2423
[9]   Implementation of a new intravenous insulin method on intermediate-care units in hospitalized patients [J].
Davis, ED ;
Harwood, K ;
Midgett, L ;
Mabrey, M ;
Lien, LF .
DIABETES EDUCATOR, 2005, 31 (06) :818-+
[10]   Glucose control and mortality in critically ill patients [J].
Finney, SJ ;
Zekveld, C ;
Elia, A ;
Evans, TW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (15) :2041-2047