Operation of High Temperature Steam Electrolyzer Module

被引:10
作者
Hartvigsen, J. [1 ]
Elangovan, S. [1 ]
O'Brien, J.
Stoots, C.
Herring, J.
机构
[1] Ceramatec Inc, Salt Lake City, UT 84119 USA
来源
SOLID OXIDE FUEL CELLS 10 (SOFC-X), PTS 1 AND 2 | 2007年 / 7卷 / 01期
关键词
D O I
10.1149/1.2729111
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A nominally 4-kW planar solid oxide stack module was operated in electrolysis mode. The module consisted of two 60-cell stacks with an integrated steam generator. The tests included both steam electrolysis to produce hydrogen and steam-carbon dioxide co-electrolysis to produce syngas. The initial performance of the module matched the performance of a 10-cell short stack. Fairly rapid initial degradation, attributed primarily to thermal imbalance from the heat duty of steam generator was noted. Reducing the heat duty of the steam generator within the thermal enclosure significantly improved the performance stability. The production of hydrogen and syngas was verified using dew point sensor and gas chromatograph.
引用
收藏
页码:357 / 363
页数:7
相关论文
共 2 条
  • [1] OBRIEN J, 2006, 2006 FUEL CELL SEM N, P332
  • [2] STOOTS C, 2006, 2006 FUEL CELL SEM N, P346