Intravascular ultrasound underestimates vessel dimensions

被引:8
作者
Tozzi, P [1 ]
Mueller, X [1 ]
Mallabiabarrena, I [1 ]
von Segesser, LK [1 ]
机构
[1] CHU Vaudois, Dept Cardiovasc Surg, Lausanne, Switzerland
关键词
vascular ultrasound; sonography; reference standards;
D O I
10.1053/ejvs.1999.1058
中图分类号
R61 [外科手术学];
学科分类号
摘要
The information gathered with intravascular ultrasound (IVUS) are of great value in endovascular techniques. The aim of this study was to evaluate the reliability of IVUS when measuring vessel dimensions by comparison with an established reference method. The left carotid artery was exposed in 4 pigs (45-55 kg) and two piezoelectric crystals were sutured on the adventitia in the same cross-sectional plane. The distance between them was measured either by IVUS and by sonomicrometers. The mean distance between the two crystals calculated by the sonomicrometer was 4.7 +/- 0.4 mm (mean systolic distance was 4.9 +/- 0.2 mm, mean diastolic distance was 4.6 +/- 0.1 mm). The mean distance between the two targets calculated by IVUS was 4.5 +/- 0.2 mm (mean systolic distance was 4.6 +/- 0.2 mm and mean diastolic 4.4 +/- 0.2 mm). Regression analysis of the two series of data shows a R-2 = 0.9984. IVUS measurements are an average 5% smaller than sonomicrometer measurements (3.6% up to 8.3%) and the difference is statistically significant (p<0.05). The underestimation of IVUS measurements will affect the accuracy, and probably the long-term outcome, of endovascular procedures.
引用
收藏
页码:501 / 503
页数:3
相关论文
共 7 条
[1]  
BEKEREDJIAN R, 1997, CIRCULATION, V96, P624
[2]   Intravascular ultrasound and stent implantation:: Intraobserver and interobserver variability [J].
Blessing, E ;
Hausmann, D ;
Sturm, M ;
Wolpers, HG ;
Amende, I ;
Mügge, A .
AMERICAN HEART JOURNAL, 1999, 137 (02) :368-371
[3]   Aortic pressure-diameter relationship assessed by intravascular ultrasound:: experimental validation in dogs [J].
Hardt, SE ;
Just, A ;
Bekeredjian, R ;
Kübler, W ;
Kirchheim, HR ;
Kuecherer, HF .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 276 (03) :H1078-H1085
[4]   Calcified plaque cross-sectional area in human arteries: Correlation between intravascular ultrasound and undecalcified histology [J].
Kostamaa, H ;
Donovan, J ;
Kasaoka, S ;
Tobis, J ;
Fitzpatrick, L .
AMERICAN HEART JOURNAL, 1999, 137 (03) :482-488
[5]   INTRAVASCULAR ULTRASOUND IMAGING - INVITRO VALIDATION AND PATHOLOGICAL CORRELATION [J].
NISHIMURA, RA ;
EDWARDS, WD ;
WARNES, CA ;
REEDER, GS ;
HOLMES, DR ;
TAJIK, AJ ;
YOCK, PG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :145-154
[6]   BALLOON-EXPANDABLE INTRACORONARY STENTS IN THE ADULT DOG [J].
SCHATZ, RA ;
PALMAZ, JC ;
TIO, FO ;
GARCIA, F ;
GARCIA, O ;
REUTER, SR .
CIRCULATION, 1987, 76 (02) :450-457
[7]  
Tobis J M, 1990, Echocardiography, V7, P415, DOI 10.1111/j.1540-8175.1990.tb00382.x