A nanoparticle-based solid-phase extraction procedure followed by flow injection inductively coupled plasma-optical emission spectrometry to determine some heavy metal ions in water samples

被引:266
作者
Faraji, Mohammad [1 ]
Yamini, Yadollah [1 ]
Saleh, Abolfazl [1 ]
Rezaee, Mohammad [1 ]
Ghambarian, Mahnaz [1 ]
Hassani, Rahim [1 ]
机构
[1] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
关键词
Heavy metal ions; Magnetic nanoparticles; Inductively coupled plasma-optical emission spectrometry; Solid-phase extraction; Water samples; ATOMIC-ABSORPTION-SPECTROMETRY; COATED MAGNETIC NANOPARTICLES; IRON-OXIDE NANOPARTICLES; MODIFIED SILICA-GEL; CAPILLARY MICROEXTRACTION; ONLINE PRECONCENTRATION; BIOLOGICAL SAMPLES; PHENOLIC-COMPOUNDS; MASS SPECTROMETRY; CD;
D O I
10.1016/j.aca.2009.11.053
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
The presented study investigates application of decanoic acid-coated Fe3O4 nanoparticles as an adsorbent for solid phase extraction and determination of trace amounts of Cd, Co, Cr, Ni, Pb and Zn from environmental water samples using flow injection inductively coupled plasma-optical emission spectrometry (ICP-OES). Magnetic nanoparticles (MNPs), carrying target metals, were easily separated from the aqueous solution by applying an external magnetic field; so, no filtration or centrifugation was necessary. After extraction and collection of MNPs, the analytes were desorbed using 0.25 mol L-1 of HCl in propanol. The desorbed analytes were introduced into the nebulizer of ICP-OES by using flow injection technique. Effects of pH, chelating agent, extraction time, type of eluent, desorption time and interfering ions on extraction efficiency of the metal ions were investigated and optimized. Under the optimized conditions, detection limits for Cd, Co, Cr, Ni, Pb and Zn were 0.3, 0.7, 0.5, 0.6, 0.8 and 0.2 mu g L-1, respectively. The enhancement factors of the proposed method for the target metal ions were in the range of 116-150, and the relative standard deviations (RSDs. C = 100 mu g L-1, n = 6) were less than 3.5%. The method had a linear dynamic range within the range of 1-400 mu g L-1. Accuracy of the method was evaluated by recovery measurements on the spiked samples, and good recoveries (92-107%) with low RSDs were achieved. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:172 / 177
页数:6
相关论文
共 38 条
[1]
Ion chromatography determination of heavy metals in airborne particulate with preconcentration and large volume direct injection [J].
Bruno, P. ;
Caselli, M. ;
De Gennaro, G. ;
Ielpo, P. ;
Ladisa, T. ;
Placentino, C. M. .
CHROMATOGRAPHIA, 2006, 64 (9-10) :537-542
[2]
Analysis of peptides and proteins affinity-bound to iron oxide nanoparticles by MALDI MS [J].
Chang, Sarah Y. ;
Zheng, Nan-Yan ;
Chen, Chee-Shan ;
Chen, Cheng-Dah ;
Chen, Ying-Yi ;
Wang, C. R. Cris .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (05) :910-918
[3]
1-(2-PYRIDYLAZO)-2-NAPHTHOL AS A POSSIBLE ANALYTICAL REAGENT [J].
CHENG, KL ;
BRAY, RH .
ANALYTICAL CHEMISTRY, 1955, 27 (05) :782-785
[4]
Analytical performance of ETAAS method for Cd, Co, Cr and Pb determination in blood fractions samples [J].
Daftsis, E. J. ;
Zachariadis, G. A. .
TALANTA, 2007, 71 (02) :722-730
[5]
GERHARDSON L, 1996, TOXICOLOGY METALS
[7]
On-line preconcentration and separation of Co, Ni and Cd via capillary microextraction on ordered mesoporous alumina coating and determination by inductively plasma mass spectrometry (ICP-MS) [J].
Hu, Wenling ;
Hu, Bin ;
Jiang, Zucheng .
ANALYTICA CHIMICA ACTA, 2006, 572 (01) :55-62
[8]
Silica-coated magnetic nanoparticles modified with γ-mercaptopropyltrimethoxysilane for fast and selective solid phase extraction of trace amounts of Cd, CuHg, and Pb in environmental and biological samples prior to their determination by inductively coupled plasma mass spectrometry [J].
Huang, Chaozhang ;
Hu, Bin .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (03) :437-444
[9]
Speciation of inorganic tellurium from seawater by ICP-MS following magnetic SPE separation and preconcentration [J].
Huang, Chaozhang ;
Hu, Bin .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (04) :760-767
[10]
Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry - Ultra trace determination of cadmium in water samples [J].
Jahromi, Elham Zeini ;
Bidari, Araz ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani ;
Jamali, Mohammad Reza .
ANALYTICA CHIMICA ACTA, 2007, 585 (02) :305-311