Liquid chromatography - electrochemical detector for the determination of glucose in rat brain combined with in vivo microdialysis

被引:41
作者
Shi, GY
Lu, JX
Xu, F
Zhou, HG
Jin, LT [1 ]
Jin, JY
机构
[1] E China Normal Univ, Sch Chem & Biol, Dept Chem, Shanghai 200062, Peoples R China
[2] Gifu Univ, Fac Engn, Dept Chem, Gifu 50111, Japan
基金
上海市自然科学基金;
关键词
glucose; CoTAPC/GOD/Nafion biosensor; LC-ECD; microdialysis sampling;
D O I
10.1016/S0003-2670(00)00753-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, microdialysis sampling was combined with liquid chromatography with electrochemical detection (LC-ECD) and glucose in rat brain was determined. A cobalt tetraaminophthalocyanine (CoTAPC)/glucose oxidase (GOD)/Nafion film-coated glassy carbon electrode was used to selectively detect the hydrogen peroxide generated enzymatically in the enzyme reactors, without any interference from electroactive species such as L-ascorbate, mate, proteins. The signal current was linearly related to the glucose concentration in the range of 1.0x10(-6)-5.0x10(-3) mol/l at +0.5 V (versus Ag/AgCl) with a detection limit of 5.0x10(-7) mol/l. To measure glucose in rat brain, microdialysis sampling was employed. The dialysate from the microdialysis system was injected into system. The result was 0.74+/-0.10 mmol/l (n=4). (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 18 条
[1]   SYNTHESIS AND STRUCTURAL STUDIES OF METAL(II) 4,9,16,23-PHTHALOCYANINE TETRAAMINES [J].
ACHAR, BN ;
FOHLEN, GM ;
PARKER, JA ;
KESHAVAYYA, J .
POLYHEDRON, 1987, 6 (06) :1463-1467
[2]  
ARNER P, 1990, J PHARMACOL EXP THER, V254, P284
[3]  
ARNER P, 1988, AM J PHYSIOL, V255, P737
[4]  
BENNUN J, 1989, INVEST OPHTH VIS SCI, V30, P1055
[5]   ELECTROCHEMICAL REDUCTION OF CARBON-DIOXIDE MEDIATED BY MOLECULAR CATALYSTS [J].
COLLIN, JP ;
SAUVAGE, JP .
COORDINATION CHEMISTRY REVIEWS, 1989, 93 (02) :245-268
[6]  
HAMBERGER A, 1989, CURR SEPARATIONS, V9, P119
[7]  
HENRIKSSON H, 1990, J NEUROL SCI, V98, P250
[8]   Amperometric biosensor for glucose based on electropolymerized tetraaminophthalocyanatocobalt(II) and phenol films [J].
Kang, TF ;
Shen, GL ;
Yu, RQ .
ANALYTICAL LETTERS, 1997, 30 (04) :647-662
[9]  
Lonnroth P, 1987, AM J PHYSIOL, V253, P228
[10]   In vivo brain glucose measurements: Differential normal pulse voltammetry with enzyme-modified carbon fiber microelectrodes [J].
Netchiporouk, LI ;
Shram, NF ;
JaffrezicRenault, N ;
Martelet, C ;
Cespuglio, R .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4358-4364