Magnetic resonance microscopy of spinal cord injury in mouse using a miniaturized implantable RF coil

被引:20
作者
Bilgen, Mehmet
机构
[1] Univ Kansas, Sch Med, Hoglund Brain Imaging Ctr, Kansas City, KS 66160 USA
[2] Univ Kansas, Sch Med, Dept Mol & Integrat Physiol, Kansas City, KS 66160 USA
关键词
magnetic resonance imaging; microscopy; inductive overcoupling; radio frequency coil; implantable coil; spinal cord;
D O I
10.1016/j.jneumeth.2006.06.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A magnetic resonance neuroimaging method is described for high-resolution imaging of spinal cord injury in live mouse. The method is based on a specially designed radio frequency coil system formed by a combination of an implantable coil and an external volume coil. The implantable coil is a 5 mm x 10 mm rectangular design with a 9.1 pF capacitor and 22 gauge copper wire and optimal for surgical implantation over the cervical or thoracic spine. The external volume coil is a standard birdcage resonator. The coils are inductively overcoupled for imaging the spinal cord at 9.4 T magnetic field strength. The inductive overcoupling provides flexibility in tuning the resonant frequency and matching the impedance of the implanted coil remotely using the tuning and matching capabilities of the volume coil. After describing the implementation of the imaging setup, in vivo data are gathered to demonstrate the imaging performance of the coil system and the feasibility of performing MR microscopy on injured mouse spinal cord. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 97
页数:5
相关论文
共 19 条
[1]   Quantitative assessment of deficits and recovery of forelimb motor function after cervical spinal cord injury in mice [J].
Anderson, KD ;
Abdul, M ;
Steward, O .
EXPERIMENTAL NEUROLOGY, 2004, 190 (01) :184-191
[2]   Simple, low-cost multipurpose RF coil for MR microscopy at 9.4 T [J].
Bilgen, M .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :937-940
[3]   Magnetic resonance imaging of mouse spinal cord [J].
Bilgen, M ;
Al-Hafez, B ;
Berman, NEJ ;
Festoff, BW .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1226-1231
[4]   A new device for experimental modeling of central nervous system injuries [J].
Bilgen, M .
NEUROREHABILITATION AND NEURAL REPAIR, 2005, 19 (03) :219-226
[5]   In vivo magnetic resonance microscopy of rat spinal cord at 7 T using implantable RF coils [J].
Bilgen, M ;
Elshafiey, I ;
Narayana, PA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1250-1253
[6]  
Bilgen M., 2006, NEUROANATOMY, V5, P12
[7]   Inductively-overcoupled coil design for high resolution magnetic resonance imaging [J].
Bilgen, Mehmet .
BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
[8]   Mouse models of human neurodegenerative disorders - Requirements for medication development [J].
Bloom, FE ;
Reilly, JF ;
Redwine, JM ;
Wu, CC ;
Young, WG ;
Morrison, JH .
ARCHIVES OF NEUROLOGY, 2005, 62 (02) :185-187
[9]   Nuclear magnetic resonance microimaging of mouse spinal cord in vivo [J].
Bonny, JM ;
Gaviria, M ;
Donnat, JP ;
Jean, B ;
Privat, A ;
Renou, JP .
NEUROBIOLOGY OF DISEASE, 2004, 15 (03) :474-482
[10]   Gender-related differences in recovery of locomotor function after spinal cord injury in mice [J].
Farooque, M ;
Suo, Z ;
Arnold, PM ;
Wulser, MJ ;
Chou, CT ;
Vancura, RW ;
Fowler, S ;
Festoff, BW .
SPINAL CORD, 2006, 44 (03) :182-187