Low versus high pressure for in vitro determination of hydraulic conductance of human dentine

被引:22
作者
Camps, J
Giustiniani, S
Dejou, J
Franquin, JC
机构
[1] IMEB EA 1787, Faculté D'odontologie, 13385 Marseille, CEDEX 5
关键词
dentine; fluid flow; permeability; pressure;
D O I
10.1016/S0003-9969(97)00013-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to evaluate the effect of applied pressure and measurement time on the in vitro measurement of hydraulic conductance of human dentine. Dentine slices were prepared from 50 third molars. Water was forced through the slices under a constant hydrostatic pressure. Five pressures were tested: 1.3 kPa (n = 10), 13.3 kPa (n = 10), 26.6 kPa (n = 10), 40 kPa (n = 10) and 53.3 kPa (n = 10). The volume that went through the slices was recorded every 10 min for 3 h. The volume, the fluid flow rate and the hydraulic conductance under the five pressures were compared. The volume increased with time and pressure. The fluid flow and hydraulic conductance decreased with time under 13.3, 26.6 and 40 kPa, bur remained constant under 1.3 and 53.3 kPa. Use of a low pressure (1.3 kPa) may permit water to pass through dentinal tubules without disturbing intratubular contents. Medium pressures (13.3, 26.6, 40 kPa) seemed to disturb tubule contents progressively, resulting in decreased fluid flow and therefore a decreased hydraulic conductance with time. Under these pressures, the calculated values of hydraulic conductance may be unreliable because they are time-dependent. High pressure (53.3 kPa) seemed to pack the tubule contents against intratubular resistances immediately, resulting in low fluid flows and low hydraulic conductances. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 20 条
[1]   INFLUENCE OF TOOTH CRYOPRESERVATION ON HUMAN DENTIN PERMEABILITY, IN-VITRO [J].
CAMPS, J ;
MARTIN, P ;
LADEQUE, P ;
RIEU, R ;
FUSERI, J .
DENTAL MATERIALS, 1994, 10 (03) :210-214
[2]   INFLUENCE OF CONCENTRATION AND APPLICATION TIME OF MALEIC-ACID ON DENTIN PERMEABILITY [J].
CAMPS, J ;
SARADELL, JM ;
DEJOU, J ;
PIGNOLY, C ;
JACQUOT, B .
DENTAL MATERIALS, 1995, 11 (03) :177-181
[3]   DENTINAL FLUID-DYNAMICS IN HUMAN TEETH, IN-VIVO [J].
CIUCCHI, B ;
BOUILLAGUET, S ;
HOLZ, J ;
PASHLEY, D .
JOURNAL OF ENDODONTICS, 1995, 21 (04) :191-194
[4]  
COMOLET R, 1984, BIOMECANIQUE CIRCULA, P25
[5]   EFFECTS OF DISTANCE FROM THE PULP AND THICKNESS ON THE HYDRAULIC CONDUCTANCE OF HUMAN RADICULAR DENTIN [J].
FOGEL, HM ;
MARSHALL, FJ ;
PASHLEY, DH .
JOURNAL OF DENTAL RESEARCH, 1988, 67 (11) :1381-1385
[6]   STORAGE EFFECTS ON DENTIN PERMEABILITY AND SHEAR BOND STRENGTHS [J].
GOODIS, HE ;
MARSHALL, GW ;
WHITE, JM ;
GEE, L ;
HORNBERGER, B ;
MARSHALL, SJ .
DENTAL MATERIALS, 1993, 9 (02) :79-84
[7]  
GOODIS HE, 1990, ARCHS ORAL BIOL, V33, P523
[8]  
Hansen S E, 1992, J Esthet Dent, V4, P169, DOI 10.1111/j.1708-8240.1992.tb00689.x
[9]   INFLUENCE OF DENTINAL FLUID AND STRESS ON MARGINAL ADAPTATION OF RESIN COMPOSITES [J].
KREJCI, I ;
KUSTER, M ;
LUTZ, F .
JOURNAL OF DENTAL RESEARCH, 1993, 72 (02) :490-494
[10]  
MAROLI S, 1992, OPER DENT, V17, P93