Investigation into the factors affecting accuracy of mass measurements on a time-of-flight mass spectrometer using Design of Experiment

被引:23
作者
Laures, Alice M. -F.
Wolff, Jean-Claude
Eckers, Christine
Borman, Phil J.
Chatfield, Marion J.
机构
[1] GlaxoSmithKline Inc, Analyt Sci, Stevenage SG1 2NY, Herts, England
[2] GlaxoSmithKline Inc, Strateg Technol, Stevenage SG1 2NY, Herts, England
[3] GlaxoSmithKline Inc, Stat Sci, Stevenage SG1 2NY, Herts, England
关键词
D O I
10.1002/rcm.2852
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The results of an investigation of the parameters which have the most significant effect on the accuracy of mass measurements on a quadrupole orthogonal acceleration time-of-flight mass spectrometer (q-oaToF) are reported. The influence of eight factors is investigated: ion abundances of reference and analyte compounds, mass difference between analyte and reference compounds, quality of calibration, number of reference acquisitions averaged and TDC (time-to-digital converter) settings (resolution, Np multiplier (number of pushes correction factor), minimum number of points, i.e. minimum acquisition width which defines a peak). To extract the maximum information from as few experiments as possible, a Design of Experiment approach was used. The data will be used as a basis for developing guidance on accurate mass measurement on q-oaToF instruments. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:529 / 535
页数:7
相关论文
共 11 条
[1]   Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer [J].
Blom, KF .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :715-719
[2]   Intercomparison study on accurate mass measurement of small molecules in mass spectrometry [J].
Bristow, AWT ;
Webb, KS .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (10) :1086-1098
[3]   Accurate mass measurements for the confirmation of Sudan azo-dyes in hot chilli products by capillary liquid chromatography-electrospray tandem quadrupole orthogonal-acceleration time of flight mass spectrometry [J].
Calbiani, F ;
Careri, M ;
Elviri, L ;
Mangia, A ;
Zagnoni, I .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) :127-135
[4]   An introduction to quadrupole-time-of-flight mass spectrometry [J].
Chernushevich, IV ;
Loboda, AV ;
Thomson, BA .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (08) :849-865
[5]   A fully automated method for accurate mass determination using high-performance liquid chromatography with a quadrupole/orthogonal acceleration time-of-flight mass spectrometer [J].
Colombo, M ;
Sirtori, FR ;
Rizzo, V .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (04) :511-517
[6]   Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept [J].
Eckers, C ;
Wolff, JC ;
Haskins, NJ ;
Sage, AB ;
Giles, K ;
Bateman, R .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3683-3688
[7]   ACCURATE MASSES FOR STRUCTURE CONFIRMATION [J].
GROSS, ML .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (02) :57-57
[8]  
HOYES J, 1999, Patent No. 9938192
[9]   Statistical design of experiments as a tool in mass spectrometry [J].
Riter, LS ;
Vitek, O ;
Gooding, KM ;
Hodge, BD ;
Julian, RK .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (05) :565-579
[10]   Investigations into the accuracy and precision obtainable on accurate mass measurements on a quadrupole orthogonal acceleration time-of-flight mass spectrometer using liquid chromatography as sample introduction [J].
Wolff, JC ;
Fuentes, TR ;
Taylor, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (11) :1216-1219