Sintering effects on mechanical properties of biologically derived dentine hydroxyapatite

被引:69
作者
Göller, G [1 ]
Oktar, FN
机构
[1] Istanbul Tech Univ, Fac Chem & Met Engn, Dept Met & Mat Engn, TR-80626 Istanbul, Turkey
[2] Marmara Univ, R&D Ctr, Istanbul, Turkey
关键词
hydroxyapatite; sintering;
D O I
10.1016/S0167-577X(02)00430-5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, the change in the mechanical properties of hydroxyapatite (HA), which is the main mineral content of bone and teeth, commonly used as an implant material, is tested for different sintering temperatures. Although HA shows great biocompatibility with the human body, its applications are limited to non-load-bearing areas and coatings due to its low mechanical properties. These mechanical properties can be improved substantially by sintering. In this study, naturally produced HA from human teeth is sintered, and density, microhardness measurements and compression tests are performed in order to find the optimum sintering temperature. The results are compared with the synthetically derived HA properties from the literature. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:142 / 147
页数:6
相关论文
共 15 条
[1]  
[Anonymous], BIOCERAMICS
[2]  
BEST S, 1990, BIOCERAMICS, V2, P57
[3]  
GOKBAYRAK H, 1993, THESIS BOGAZICI U
[4]   PLASMA SPRAYING OF BIOLOGICALLY DERIVED HYDROXYAPATITE ON IMPLANTABLE MATERIALS [J].
JOSHI, SV ;
SRIVASTAVA, MP ;
PAL, A ;
PAL, S .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1993, 4 (03) :251-255
[5]   4 CALCIUM-PHOSPHATE CERAMICS AS BONE SUBSTITUTES FOR NON-WEIGHT-BEARING [J].
KITSUGI, T ;
YAMAMURO, T ;
NAKAMURA, T ;
KOTANI, S ;
KOKUBO, T ;
TAKEUCHI, H .
BIOMATERIALS, 1993, 14 (03) :216-224
[6]   Stability of hydroxyapatite while processing short-fibre reinforced hydroxyapatite ceramics [J].
Knepper, M ;
Moricca, S ;
Milthorpe, BK .
BIOMATERIALS, 1997, 18 (23) :1523-1529
[7]  
Koempel JA, 1998, J BIOMED MATER RES, V41, P359, DOI 10.1002/(SICI)1097-4636(19980905)41:3<359::AID-JBM3>3.0.CO
[8]  
2-B
[9]   Characterization of processed tooth hydroxyapatite for potential biomedical implant applications [J].
Oktar, FN ;
Kesenci, K ;
Piskin, E .
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY, 1999, 27 (04) :367-379
[10]   SINTERING EFFECTS ON THE STRENGTH OF HYDROXYAPATITE [J].
RUYS, AJ ;
WEI, M ;
SORRELL, CC ;
DICKSON, MR ;
BRANDWOOD, A ;
MILTHORPE, BK .
BIOMATERIALS, 1995, 16 (05) :409-415