Biosensing of hydrogen peroxide at carbon paste electrode incorporating N-methyl phenazine methosulphate, fumed-silica and horseradish peroxidase

被引:7
作者
Luo, WL
Liu, HY
Deng, HH
Sun, K
Zhao, CH
Qi, DY
Deng, JQ
机构
[1] SHANGHAI UNIV, DEPT CHEM & CHEM ENGN, SHANGHAI 200072, PEOPLES R CHINA
[2] FUDAN UNIV, DEPT CHEM, SHANGHAI 200433, PEOPLES R CHINA
基金
上海市自然科学基金;
关键词
biosensor; N-methyl phenazine methosulphate; horseradish peroxidase; hydrogen peroxide; fumed silica; carbon paste electrode;
D O I
10.1080/00032719708002797
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensing of hydrogen peroxide was made at a carbon paste electrode incorporating fumed silica, horseradish peroxidase and N-methyl phenazine methosulphate. Cyclic voltammetric and amperometric measurements were used for the first time to demonstrate the suitability of electron communication between horseradish peroxidase and a carbon paste electrode via N-methyl phenazine methosulphate, an electron transfer mediator. Performance and characteristics of the biosensor were evaluated with respect to response time, detection limit, applied potential and concentration of the mediator. Effect of applied potential and amount of the mediator in carbon paste on the Michaelis-Menten constant of the biosensor was investigated. The biosensor possessed a variety of characteristics including long stability and rapid response and high sensitivity to hydrogen peroxide, with a detection limit of 0.08 mu M.
引用
收藏
页码:205 / 220
页数:16
相关论文
共 37 条
[1]   PHOTOVOLTAIC DETERMINATION OF HYDROGEN-PEROXIDE WITH A BIOPHOTODIODE [J].
AIZAWA, M ;
IKARIYAMA, Y ;
KUNO, H .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1984, 17 (07) :555-564
[2]   LUMINOL CHEMILUMINESCENCE REACTION CATALYZED BY A MICROBIAL PEROXIDASE [J].
AKIMOTO, K ;
SHINMEN, Y ;
SUMIDA, M ;
ASAMI, S ;
AMACHI, T ;
YOSHIZUMI, H ;
SAEKI, Y ;
SHIMIZU, S ;
YAMADA, H .
ANALYTICAL BIOCHEMISTRY, 1990, 189 (02) :182-185
[3]   TTF-MODIFIED BIOSENSORS FOR HYDROGEN-PEROXIDE [J].
BIFULCO, L ;
CAMMAROTO, C ;
NEWMAN, JD ;
TURNER, APF .
ANALYTICAL LETTERS, 1994, 27 (08) :1443-1452
[4]   BIOAMPEROMETRIC SENSORS FOR PHENOL BASED ON CARBON PASTE ELECTRODES [J].
BONAKDAR, M ;
VILCHEZ, JL ;
MOTTOLA, HA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (01) :47-55
[5]   EPHEDRINE DETERMINATION IN HUMAN URINE USING A CARBON-PASTE ELECTRODE MODIFIED WITH C-18 BONDED SILICA-GEL [J].
CHICHARRO, M ;
ZAPARDIEL, A ;
BERMEJO, E ;
PEREZ, JA ;
HERNANDEZ, L .
ANALYTICAL LETTERS, 1994, 27 (10) :1809-1831
[6]   SPECTROPHOTOMETRIC DETERMINATION OF HYDROGEN-PEROXIDE AFTER EXTRACTION WITH ETHYL-ACETATE [J].
CLAPP, PA ;
EVANS, DF ;
SHERIFF, TSS .
ANALYTICA CHIMICA ACTA, 1989, 218 (02) :331-334
[7]   PEROXIDASE-MODIFIED CARBON-FIBER MICROELECTRODES IN FLOW-THROUGH DETECTION OF HYDROGEN-PEROXIDE AND ORGANIC PEROXIDES [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G ;
TUDOS, AJ ;
KOK, WT .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3604-3610
[8]   A METHOD FOR ESTIMATION OF HYDROGEN-PEROXIDE BASED ON MEDIATED ELECTRON-TRANSFER REACTIONS OF PEROXIDASES AT ELECTRODES [J].
FREW, JE ;
HARMER, MA ;
HILL, HAO ;
LIBOR, SI .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 201 (01) :1-10
[9]   AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER [J].
GARGUILO, MG ;
HUYNH, N ;
PROCTOR, A ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :523-528
[10]   AMPEROMETRIC GLUCOSE SENSORS BASED ON IMMOBILIZED GLUCOSE-OXIDIZING ENZYMES AND CHEMICALLY MODIFIED ELECTRODES [J].
GORTON, L ;
BREMLE, G ;
CSOREGI, E ;
JONSSONPETTERSSON, G ;
PERSSON, B .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :43-54