Computer assisted detection software for CT colonography: effect of sphericity filter on performance characteristics for patients with and without fecal tagging

被引:14
作者
Dehmeshki, Jamshid
Halligan, Steve
Taylor, Stuart A.
Roddie, Mary E.
McQuillan, Justine
Honeyfield, Lesley
Amin, Hamdan
机构
[1] UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
[2] Medicsight PLC, London, England
[3] Charing Cross Hosp, London, England
关键词
colon (CT); colonography (CT); colon cancer; computer-assisted detection;
D O I
10.1007/s00330-006-0430-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study is to investigate the effect of changing sphericity filter values on performance of a computer assisted detection (CAD) system for CT colonography for data with and without fecal tagging. Colonography data from 138 patients with 317 validated polyps were divided into those with (86) and without (52) fecal tagging. Polyp coordinates were established by three observers and datasets analysed subsequently by a proprietary CAD system used at four discrete sphericity filter settings. Prompts were compared with the known coordinates in order to determine sensitivity and specificity. Sensitivity was highest at low sphericity; of 164 polyps 6 mm or more, 144 (87.8%) were detected at sphericity 0.3, and 132 (80.1%) at sphericity 0.9. Of 42 polyps measuring 10 mm or more, 40 (95.2%) were detected at sphericity 0.3, and 36 (85.7%) at sphericity 0.9. There was no significant difference in sensitivity for tagged and un-tagged data but specificity was reduced in tagged data at low sphericity and significantly reduced in untagged data at high sphericity. CAD had a sensitivity of 95.2% for polyps measuring 1 cm or more and 87.8% for polyps 6 mm or more when used at a sphericity setting of 0.3. Higher sphericity settings increased specificity while reducing sensitivity. The bowel preparation used significantly impacts on specificity.
引用
收藏
页码:662 / 668
页数:7
相关论文
共 21 条
[1]  
Altman DG, 2000, STAT MED, V19, P453, DOI 10.1002/(SICI)1097-0258(20000229)19:4<453::AID-SIM350>3.3.CO
[2]  
2-X
[3]   Consensus on current clinical practice of virtual colonoscopy [J].
Barish, MA ;
Soto, JA ;
Ferrucci, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (03) :786-792
[4]   Computer-aided detection (CAD) for CT colonography: a tool to address a growing need [J].
Bogoni, L ;
Cathier, P ;
Dundar, M ;
Jerebko, A ;
Lakare, S ;
Liang, J ;
Periaswamy, S ;
Baker, ME ;
MacAri, M .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 :S57-S62
[5]   Polyp measurement and size categorisation by CT colonography: effect of observer experience in a multi-centre setting [J].
Burling, David ;
Halligan, Steve ;
Altman, Douglas G. ;
Atkin, Wendy ;
Bartram, Clive ;
Fenlon, Helen ;
Laghi, Andrea ;
Stoker, Jaap ;
Taylor, Stuart ;
Frost, Roger ;
Dessey, Guido ;
De Villiers, Melinda ;
Florie, Jasper ;
Foley, Shane ;
Honeyfield, Lesley ;
Iannaccone, Riccardo ;
Gallo, Teresa ;
Kay, Clive ;
Lefere, Philippe ;
Lowe, Andrew ;
Mangiapane, Filipo ;
Marrannes, Jesse ;
Neri, Emmanuele ;
Nieddu, Giulia ;
Nicholson, David ;
O'Hare, Alan ;
Ori, Sante ;
Politi, Benedetta ;
Poulus, Martin ;
Regge, Daniele ;
Renaut, Lisa ;
Rudralingham, Velauthan ;
Signoretta, Saverio ;
Vagli, Paola ;
Van der Hulst, Victor ;
Williams-Butt, Jane .
EUROPEAN RADIOLOGY, 2006, 16 (08) :1737-1744
[6]   CT colonography interpretation times: effect of reader experience, fatigue, and scan findings in a multi-centre setting [J].
Burling, David ;
Halligan, Steve ;
Altman, Douglas G. ;
Atkin, Wendy ;
Bartram, Clive ;
Fenlon, Helen ;
Laghi, Andrea ;
Stoker, Jaap ;
Taylor, Stuart ;
Frost, Roger ;
Dessey, Guido ;
De Villiers, Melinda ;
Florie, Jasper ;
Foley, Shane ;
Honeyfield, Lesley ;
Iannaccone, Riccardo ;
Gallo, Teresa ;
Kay, Clive ;
Lefere, Philippe ;
Lowe, Andrew ;
Mangiapane, Filipo ;
Marrannes, Jesse ;
Neri, Emmanuele ;
Nieddu, Giulia ;
Nicholson, David ;
O'Hare, Alan ;
Ori, Sante ;
Politi, Benedetta ;
Poulus, Martin ;
Regge, Daniele ;
Renaut, Lisa ;
Rudralingham, Velauthan ;
Signoretta, Saverio ;
Vagli, Paola ;
Van der Hulst, Victor ;
Williams-Butt, Jane .
EUROPEAN RADIOLOGY, 2006, 16 (08) :1745-1749
[7]   Assessment methodologies and statistical issues for computer-aided diagnosis of lung nodules in computed tomography: Contemporary research topics relevant to the lung image database consortium [J].
Dodd, LE ;
Wagner, RF ;
Armato, SG ;
McNitt-Gray, MF ;
Beiden, S ;
Chan, HP ;
Gur, D ;
McLennan, G ;
Metz, CE ;
Petrick, N ;
Sahiner, B ;
Sayre, J .
ACADEMIC RADIOLOGY, 2004, 11 (04) :462-475
[8]   A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps [J].
Fenlon, HM ;
Nunes, DP ;
Schroy, PC ;
Barish, MA ;
Clarke, PD ;
Ferrucci, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (20) :1496-1503
[9]   Multiple neural network classification scheme for detection of colonic polyps in CT colonography data sets [J].
Jerebko, AK ;
Malley, JD ;
Franaszek, M ;
Summers, RM .
ACADEMIC RADIOLOGY, 2003, 10 (02) :154-160
[10]   Computerized tomographic colonography: Performance evaluation in a retrospective multicenter setting [J].
Johnson, CD ;
Toledano, AY ;
Herman, BA ;
Dachman, AH ;
McFarland, EG ;
Barish, MA ;
Brink, JA ;
Ernst, RD ;
Fletcher, JG ;
Halvorsen, RA ;
Hara, AK ;
Hopper, KD ;
Koehler, RE ;
Lu, DSK ;
Macari, M ;
MacCarty, RL ;
Miller, FH ;
Morrin, M ;
Paulson, EK ;
Yee, J ;
Zalis, M .
GASTROENTEROLOGY, 2003, 125 (03) :688-695