Ceramic-on-ceramic bearings in total hip arthroplasty

被引:102
作者
Bierbaum, BE [1 ]
Nairus, J [1 ]
Kuesis, D [1 ]
Morrison, JC [1 ]
Ward, D [1 ]
机构
[1] New England Baptist Hosp, Dept Orthopaed, Boston, MA 02120 USA
关键词
D O I
10.1097/01.blo.0000038043.63743.9f
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The ideal bearing surface for total hip arthroplasty still is being sought. This bearing would be durable, cost-effective, easy to implant, inert, and produce minimal wear debris. Ceramic-on-ceramic bearings have continued to evolve and have enjoyed success in many European centers throughout the past 3 decades. A limited number of early reports from the United States discouraged widespread acceptance and use of ceramic-on-ceramic total hip arthroplasty. Once critically analyzed most of the failures from the early reports are attributable to design and material specific flaws. Vast improvements have been made in ceramic manufacturing leading to even more superior wear characteristics and higher burst strengths. The case for alumina-on-alumina ceramic bearings is becoming stronger as data accumulate clinically and in vitro. In a multicenter, prospective and randomized study, an alumina-on-alumina ceramic bearing is compared with a cobalt chrome-on-polyethylene bearing. After as many as 48 months there has been no significant difference in clinical performance between the two study groups. No ceramic head fracture or ceramic bearing failure has occurred. Therefore, this new alumina-on-alumina ceramic bearing is a safe option for total hip arthroplasty and may provide a more durable prosthesis especially in young and active patients.
引用
收藏
页码:158 / 163
页数:6
相关论文
共 34 条
[1]
Poor eight-year survival of cemented zirconia-polyethylene total hip replacements [J].
Allain, J ;
Le Mouel, S ;
Goutallier, D ;
Voisin, MC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :835-842
[2]
Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head - A case report [J].
Allain, J ;
Goutallier, D ;
Voisin, MC ;
Lemouel, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (09) :1355-1360
[3]
[Anonymous], SEMIN ARTHROPLAST
[4]
[Anonymous], BONE IMPLANT INTERFA
[5]
THE USE OF DENSE ALUMINA ALUMINA CERAMIC COMBINATION IN TOTAL HIP-REPLACEMENT [J].
BOUTIN, P ;
CHRISTEL, P ;
DORLOT, JM ;
MEUNIER, A ;
DEROQUANCOURT, A ;
BLANQUAERT, D ;
HERMAN, S ;
SEDEL, L ;
WITVOET, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12) :1203-1232
[6]
Catelas I, 1998, J BIOMED MATER RES, V41, P600, DOI 10.1002/(SICI)1097-4636(19980915)41:4<600::AID-JBM12>3.0.CO
[7]
2-I
[8]
Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro [J].
Catelas, I ;
Petit, A ;
Marchand, R ;
Zukor, DJ ;
Yahia, LH ;
Huk, OL .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (03) :516-521
[9]
New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Bierbaum, B .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :390-397
[10]
DORLOT JM, 1992, CLIN ORTHOP RELAT R, P47