A high-frequency pulsed-wave doppler ultrasound system for the detection and imaging of blood flow in the microcirculation

被引:79
作者
Christopher, DA [1 ]
Burns, PN [1 ]
Starkoski, BG [1 ]
Foster, FS [1 ]
机构
[1] UNIV TORONTO, SUNNYBROOK HLTH SCI CTR, DEPT MED BIOPHYS, TORONTO, ON M4N 3M5, CANADA
关键词
Doppler ultrasound; pulsed-wave Doppler; high-frequency ultrasound; microcirculation; blood velocity measurement; colour Doppler imaging; power Doppler imaging; ultrasound backscatter microscope; duplex Doppler; ultrasonics;
D O I
10.1016/S0301-5629(97)00076-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Previous work with a 40-MHz continuous-wave Doppler ultrasound system has demonstrated the potential of high-frequency Doppler ultrasound (HFD), operating in the frequency range 20-200 MHz, to detect blood flow in the microcirculation, This paper describes a directional, pulsed-wave high-frequency Doppler ultrasound (PW HFD) system that was designed and constructed further to investigate this potential, The PW HFD system electronics have a dynamic range of > 80 dB, a noise floor of 250 nV, a directional isolation of 45 dB and operate over the frequency range 1-200 MHz, The system is tested using a focused PVDF transducer that is tuned for maximum sensitivity at 50 MHz, has a -6 dB lateral beamwidth of 70 mu m and -6 dB depth-of-focus of 0.90 mm, This permits the practical use of sample volumes with dimensions 70 mu m laterally by 90-900 mu m axially, The PW HFD system can operate in duplex mode by either sharing the Doppler transducer or using a second PVDF transducer for imaging, Tests with string and capillary flow phantoms demonstrate that the PW HFD system is capable of detecting velocities on the order of the blood velocities found in the capillaries (0.5 mm/s) and arterioles (5 mm/s) with suitable velocity (30-300 mu m/s) and temporal (15-100 ms) resolutions, Dt vivo measurements demonstrate that PW HFD can detect and measure blood velocities of less than 5 mm/s in arterioles and venules with diameters as small as 20 mu m and 35 mu m, respectively, using a sample volume of only 70 mu m laterally by 150 mu m axially, Preliminary experiments with high-frequency colour Doppler (HFCD) rind high-frequency power Doppler (HFPD) imaging are also presented, (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:997 / 1015
页数:19
相关论文
共 61 条
[1]  
*AIUM STAND COMM, 1993, PERF CRIT MEAS DOPPL
[2]  
[Anonymous], [No title captured]
[3]  
ATKINSON P, 1982, DOPPLER ULTRASOUND I
[4]   THE HAIRLESS MOUSE EAR FOR INVIVO STUDIES OF SKIN MICROCIRCULATION [J].
BARKER, JH ;
HAMMERSEN, F ;
BONDAR, I ;
UHL, E ;
GALLA, TJ ;
MENGER, MD ;
MESSMER, K .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 83 (06) :948-959
[5]  
BASLER S, 1989, BIOMAT ART CELLS ART, V17, P61
[6]   VERY HIGH-FREQUENCY PULSED DOPPLER APPARATUS [J].
BERSON, M ;
PATAT, F ;
WANG, ZQ ;
BESSE, D ;
POURCELOT, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (02) :121-131
[7]   KAPPA-DELTA AWARD PAPER - PULSED ULTRASOUND DOPPLER VELOCIMETRY IN THE ASSESSMENT OF MICROVASCULAR HEMODYNAMICS [J].
BLAIR, WF ;
BROWN, TD ;
GREENE, ER .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (02) :300-309
[8]   TOPOFLOW - DIGITAL FULL RANGE DOPPLER VELOCITY METER [J].
BRANDESTINI, M .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (05) :287-293
[9]   SOME CHARACTERISTICS OF LAMINAR-FLOW VELOCITY SPECTRA DETECTED BY A 20 MHZ PULSED ULTRASOUND DOPPLER [J].
BROWN, TD ;
GABEL, RH ;
PEDERSEN, DR ;
BELL, LD ;
BLAIR, WF .
JOURNAL OF BIOMECHANICS, 1985, 18 (12) :927-+
[10]  
BROWN TD, 1985, J BIOMED ENG, V107, P284