Disease-specific, patient-assessed measures of health outcome in ankylosing spondylitis: reliability, validity and responsiveness

被引:73
作者
Haywood, KL
Garratt, AM
Jordan, K
Dziedzic, K
Dawes, PT
机构
[1] Coventry Univ, Sch Hlth & Social Sci, Interdisciplinary Res Ctr Hlth, Physiotherapy & Dietet Subject Grp, Coventry CV1 5FB, W Midlands, England
[2] Univ York, Dept Hlth Sci & Clin Evaluat, York YO1 5DD, N Yorkshire, England
[3] Univ Oxford, Unit Hlth Care Epidemiol, Inst Hlth Sci, Oxford OX3 7LF, England
[4] Univ Keele, Primary Care Sci Res Ctr, Keele ST5 5BG, Staffs, England
[5] Univ Keele, Dept Physiotherapy Studies, Keele ST5 5BG, Staffs, England
[6] Staffordshire Rheumatol Ctr, Stoke On Trent ST6 7AG, Staffs, England
关键词
ankylosing spondylitis; patient-assessed health outcome; reliability; responsiveness; validity;
D O I
10.1093/rheumatology/41.11.1295
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To assess the acceptability and measurement properties of four ankylosing spondylitis (AS)-specific, patient-assessed measures of health outcome: AS Quality of Life Questionnaire (ASQoL), Bath AS Disease Activity Index (BASDAI), the Body Chart and the Revised Leeds Disability Questionnaire (RLDQ). Methods. Instruments were administered by means of a self-completed questionnaire to patients recruited from across the United Kingdom (UK). Instruments were assessed for data quality and scaling assumptions. Where appropriate, dimensionality was assessed using principle component analysis (PCA). Internal consistency reliability was tested using Cronbach's alpha. Test-retest reliability was assessed in those patients reporting no change in AS-specific health at 2 weeks. The convergent validity of the instruments was assessed and scores were correlated with responses to the health transition questions. Responsiveness was assessed for patients reporting change in health at 6 months. Results. The BASDAI and Body Chart have low self-completion rates. Item responses for the RLDQ were skewed towards higher levels of functional ability. PCA supported instrument unidimensionality. Cronbach's alpha ranged from 0.87 (BASDAI) to 0.93 (RLDQ). Test-retest reliability estimates support the use of the ASQoL and RLDQ in individual evaluation (>0.90). Correlations between instruments were in the hypothesized direction; the largest was between the ASQoL and BASDAI (0.79). The BASDAI had the strongest linear relationship, with responses to both specific and general health transition questions (P<0.01). With the exception of the Body Chart, instruments had a stronger relationship with general health transition. The BASDAI was the most responsive instrument. The Body Chart and RLDQ had low levels of responsiveness. Conclusion. The instruments have undergone a comprehensive comparative evaluation to assess the measurement properties required for patient-assessed measures of health outcome. Adequate levels of reliability and validity were found for all instruments. The BASDAI and the ASQoL were the most responsive to self-perceived change in health, but the BASDAI had low levels of self-completion.
引用
收藏
页码:1295 / 1302
页数:8
相关论文
共 37 条
[1]  
ABBOTT CA, 1994, BRIT J RHEUMATOL, V33, P1060
[2]  
ALTMAN DG, 1996, PRACTICAL STAT MED R
[3]  
[Anonymous], HLTH TECHNOLOGY ASSE
[4]  
CALIN A, 1994, J RHEUMATOL, V21, P2281
[5]   REPRODUCIBILITY AND RESPONSIVENESS OF HEALTH-STATUS MEASURES - STATISTICS AND STRATEGIES FOR EVALUATION [J].
DEYO, RA ;
DIEHR, P ;
PATRICK, DL .
CONTROLLED CLINICAL TRIALS, 1991, 12 (04) :S142-S158
[6]  
DOUGADOS M, 1988, J RHEUMATOL, V15, P302
[7]  
DZIEDZIC K, 1998, RHEUMATOLOGICAL PHYS, P97
[8]  
DZIEDZIC KSG, 1997, THESIS U KEELE STAFF
[9]  
FITZPATRICK R, 1993, BRIT J RHEUMATOL, V32, P807
[10]   THE MEASUREMENT OF HEALTH-STATUS AND QUALITY-OF-LIFE IN RHEUMATOLOGICAL DISORDERS [J].
FITZPATRICK, R .
BAILLIERES CLINICAL RHEUMATOLOGY, 1993, 7 (02) :297-317